Imperial, Essence, Principal & Qadrical 

(Clean Burn) Stoves 

APPROVED FOR BURNING WOOD AND SMOKELESS COAL IN A SMOKE 

CONTROLLED AREA  

CE APPROVED.   

 

 

 

 

 

 

 

 

 

 

Clean burn cast iron multi fuel stove 

Installation & operating instructions.  To be left with user. 

 

This appliance must be installed by a competent person and must comply 

with all building regulations including those referring to local authority by-

laws, National and European Codes of Practice. Unless the installer is 
qualified to approve the installation, then approval must be sought from 

your local building control officer. It is an offence under UK law not to 

comply with this advice. After installation the appliance should be ready 
for use and instruction as to use and control given. The customer should be 

advised to only use recommended fuels and also given advice on what to 

do should smoke or fumes be emitted from the stove. 

 

01462

 

813138

 

15JUL03/EQIP/V1.4 dated

 

03

rd

July 2015

Summary of Contents for Essence

Page 1: ...l authorities may declare the whole or part of the district of the authority to be a smoke control area It is an offence to emit smoke from a chimney of a building from a furnace or from any fixed boiler if located in a designated smoke control area It is also an offence to acquire an unauthorised fuel for use within a smoke control area unless it is used in an exempt appliance exempted from the c...

Page 2: ...ilding regulations including those referring to local authority by laws National and European Codes of Practice Unless the installer is qualified to approve the installation then approval must be sought from your local building control officer It is an offence under UK law not to comply with this advice After installation the appliance should be ready for use and instruction as to use and control ...

Page 3: ...fireplace should be filled in so that there is a smooth streamlined entry into the flue All of the installation must be in accordance with BS 8303 1994 As long as only approved clean burn fuels are to be used and the flue draw is recorded as a minimum of 12 Pascals then a maximum horizontal length of 450mm is permissible It is essential that all connections between the stove and chimney flue are s...

Page 4: ...n the presence of children the elderly or the infirm Inform all persons of the dangers of high temperatures during operation of appliance including the stove pipe and use the operating tools provided The glove provided is a tool Do not over fire it is possible to fire the stove beyond its design capacity This could damage the stove so watch for signs of over firing if any part of the stove starts ...

Page 5: ...ty of your chimney consult your local dealer stockist The chimney must be swept before connection to the stove and swept every six months thereafter If there is an excessive build up of soot then the chimney must be swept and the reason for build up investigated An existing fireplace opening can be bricked up or sealed with a register plate 2 5mm steel sheet or concrete A short length of flue pipe...

Page 6: ...lied in desired position for legs locate legs fit washers and nuts and tighten Lean stove forwards and prop under base panel fit rear legs using studs washers and nuts provided Note the Imperial Essence Principal and Qadrical Stoves are heavy take care when handling Clean Burn Kit Installation Instructions FOR INSTALLER ONLY 1 Open the stove door 2 Slide the secondary air control completely to the...

Page 7: ...ould be warned to use a fireguard to BS 8423 2002 Replaces BS 6539 in the presence of children aged and or infirm persons CO Alarms Building regulations require that when ever a new or replacement fixed solid fuel or wood biomass appliance is installed in a dwelling a carbon monoxide alarm must be fitted in the same room as the appliance Further guidance on the installation of the carbon monoxide ...

Page 8: ...es have no ventilation requirement in houses build before 2008 but a fixed vent is advisable as this will enhance the pull of the chimney and reduce unwanted draughts Care should be taken that these openings cannot become obstructed Considerations and provisions must be made for any other appliances requiring ventilation An extractor fan should not be used in the same location as the appliance Thi...

Page 9: ...e over fuel quality or suitability consult your local supplier or the solid fuel advisory service PETROLEUM COKE FUELS OR HOUSEHOLD WASTE SHOULD NOT BE BURNT IN THIS APPLIANCE Should any difficulties arise over fuel quality or suitability consult your local supplier or the solid fuel advisory service 8 Safety Notes For Your Guidance FIRES CAN BE DANGEROUS Always use a fire guard to BS8423 2002 spe...

Page 10: ... fuel is removed by riddling periodically If ash is allowed to build up it will stifle the air flow through the grate and fuel and eventually cause the fire to die Do not let the ash build up to the underside of the grate bars this will severely reduce the life of the grate and prevent efficient burning With some solid fuels a residue of burnt fuel or clinker will accumulate on the grate allow the...