background image

WSD10TII 

User Manual

 

 

 

 

 

PAGE   11/11

 

 

WA0425_WSD10TII_User Manual_R02 V6.0 

 

www.

capetti

.it 

14.

 

Reference standards. 

 

EN 61010 -1 

For electromagnetic compatibility 

EN 61000 - 3 - 2 
EN 61000 - 3 - 3 
EN 300 220 -2 
EN 301 489 - 03 
EN 61000 - 6 -1 

 

 

This symbol indicates that this product is compliant with the European Directive 2011/65/CE that restricts 
the use of substances in the manufacturing of electronic devices.

 

 

 

 

 

 

The “WEEE” logo on the label indicates that this product is compliant with the "WEEE" EC Directive. This 

symbol (valid only in the European Union countries) indicates that the product it is applied to, MUST 
NOT  be  discarded  with  ordinary  household  or  industrial  waste,  but  must  be  sent  to  an  authorized 
reception point. The end user should contact the device provider, either the manufacturer or the reseller, 
to agree a collection and disposal process, after having checked the terms and conditions of sale.

 

 

 

 

 

 

IT1902000001116
1

 

Summary of Contents for WSD10TII

Page 1: ...WSD10TII User Manual ...

Page 2: ...ct the electronic boards without removing batteries before ALWAYS substitute all the batteries also in case of one single battery exhausted If the device is powered by a fixed network make sure you have disconnected the power supply before carrying out any type of intervention Failure to comply with this indication can cause damage to people and or property Follow the manufacturer s suggested warm...

Page 3: ...wo thresholds for each inclination channel can be setup two thresholds for CH2 and two thresholds for CH3 Measure sample will be compared with thresholds values with interval obtained by Threshold Following interval value c Value following Step answer Every Threshold Following interval will be compared to the instant value average acquired in a time frame of 8 seconds with the current sample If th...

Page 4: ...nfigurations Device default configurations at the first starting are the following Measure interval 60 minutes Threshold Following interval 5 minutes CH2 and CH3 Follower Enabled with Delta Increase 6 and Delta Decrease 6 Picture 2 Device setup using gateway Picture 3 Channels Axis correspondance ...

Page 5: ...re 5 Command table that means it s ready for connecting to an existing system in order to associate it make reference to the WineCap System User Manual R30 software manual It is necessary to use the WineCapManager software on the PC connected to the gateway that will be linked with the device 8 Wireless device user interface The user interface consists of a virtual button that can be activated usi...

Page 6: ...ess and the radio are is turned off losing the connection to the network To reactivate a TEST command is necessary The STANDBY command must be given twice to confirm it at the first sequence the led flashes alternating RED and GREEN lights waiting for the second confirm sequence within 15 seconds At the command execution the led flashes as the STANDBY status refer to Picture 6 Status table Wireles...

Page 7: ...ponding at the desired command The TEST corresponds to the second pulse and activate the Field Measurer function The device will give back the radio signal quality through led flashes WIRELESS MODE STATUS Table FLASH COUNT WIRELESS MODE STATUS RADIO SIGNAL QUALITY 5 green flashes ACTIVE Radio signal Excellent 4 green flashes ACTIVE Radio signal Good 3 green flashes ACTIVE Radio signal Fair 2 amber...

Page 8: ...e issued twice to confirm the operation Position the WineCapKey in the spot indicated in Picture 4 WineCapKey positioning and wait for four AMBER flashes then remove the WineCapKey from device Verify that the device asks for confirmation of STANDBY command with alternate GREEN RED flashing then position again the WineCapKey and wait for four flashes again The device will confirm the STANDBY status...

Page 9: ...50x60mm Weight 990g Case material ABS Galvanized iron bracket Mounting 4 holes 9mm diameter Gluing using optional bracket FIX WSD10TII Magnetic using FIX MAG WSD10TII with 28Kg total traction force Connections Wireless Inclination Transducer type Three axis accelerometer Inclination Measure range 6 5000 in all the installation positions Automatic zeroing using command issued with WineCapKey Inclin...

Page 10: ...WSD10TII User Manual PAGE 10 11 WA0425_WSD10TII_User Manual_R02 V6 0 www capetti it 13 Mechanical dimensions Picture 7 Mechanical dimensions ...

Page 11: ...the manufacturing of electronic devices The WEEE logo on the label indicates that this product is compliant with the WEEE EC Directive This symbol valid only in the European Union countries indicates that the product it is applied to MUST NOT be discarded with ordinary household or industrial waste but must be sent to an authorized reception point The end user should contact the device provider ei...

Reviews: