background image

 

 

 

 

 

 

 

REV04 

 

CAPETTI ELETTRONICA s.r.l.  -   Strada Stratta 57 

10090 CASTIGLIONE TORINESE  -  TORINO  -  ITALY 
VAT 04837130014 - Phone 011.981.98.11 -  Fax 011.981.98.210 

e-mail [email protected]  -  web www.capetti.it

 

 

2/6

 

 

MWDG-ETH 

LAN Configuration Manual 

 

d.

 

If  the  upload  is  successful,  the  CCS  led  turns  off  after  few  minutes.  In  case  of  malfunction  the  CCS  led  will 
turns in red.

 

3.

 

Device Installer. 

To  know  the  IP  address  of  the  basestation,  the  management  software  named  “DeviceInstaller”,  contained  on  the 
provided setup CD Rom, must be installed; 

a.

 

Connect the PC using the cable to the same LAN of the 

MWDG-ETH

. Otherwise, a direct connection between 

the PC and the 

basestation

 can be setup (

using the ethernet cable

); 

b.

 

Install and execute “DeviceInstaller” from Program menu, in the Lantronix directory; 

c.

 

Select  the  Tools  menu 

  Options  and  click  on  the  proper  network  adapter  (

typically  is  named  “Local  LAN 

Connection”

); 

d.

 

Click on “Search” button; 

e.

 

If the search is successful, in the device list will appear an element named “xPico”; 

f.

 

Double click on the element; if a popup with a firewall exception appears, click on “Allow”; 

g.

 

Click on this device the window “Web Configuration” can be selected. On the address bar the IP address of 
the module will appear; 

h.

 

Click “send” from theaddress bar. Otherwise is possible to cut and paste this address on the PC browser; 

i.

 

An authentication is requested: if user name and password are not set, leave these fields blank and click  on 
“OK”; 

j.

 

The “

Web Manager”

 management page for ethernet peripherals will opens. 

Summary of Contents for Wine Cap MWDG-ETH

Page 1: ... install and use the DeviceInstaller software to reach the basestation Please refer to DeviceInstaller chapter 2 Service Center Connection In order to obtain Internet access and download data to the Service Center WineCap www winecap it external server the DHCP service or the manual setup of the network configuration must provide the insertion of the Gateway IP and DNS server useful for the extern...

Page 2: ...can be setup using the ethernet cable b Install and execute DeviceInstaller from Program menu in the Lantronix directory c Select the Tools menu Options and click on the proper network adapter typically is named Local LAN Connection d Click on Search button e If the search is successful in the device list will appear an element named xPico f Double click on the element if a popup with a firewall e...

Page 3: ... web www capetti it 3 6 MWDG ETH LAN Configuration Manual 4 Web Manager Using Web Manager is possible to modify a Device IP address click on Network from the menu located on the left and setup fields as desired i Obtain IP address automatically for automatic configuration ii Use the following IP configuration to setup IP address Subnet Gateway and DNS in static mode ...

Page 4: ...t only in the Endpoint configuration section other parameters must not be modified This allows to use the virtual COM port on TCP through a port enabled to communication ATTENTION Local Port must be different from 23 Connessione MODBUS RTU over TCP La basestation può essere interrogata da remoto attraverso i c Saving every time a parameter is changed the OK button in the bottom of the page must be...

Page 5: ...nager management software To use WineCapManager the ComPortRedirector software available on the provided CD Rom must be installed After program installation a virtual COMx serial port can be configured pay attention to don t configure an existing or busy port and addressed to the IP address and the Modbus TCP port where the MWDG ETH basestation has been configured please refer to WebManager chapte...

Page 6: ...e saving is necessary to make changes operative In the COM port list available on Windows a new port will appear useful to connect to the MWDG basestation through WineCapManager When WineCapManager is executed select Local Connection at the connection type prompt The software check for all the COM ports available on the system up to find a valid MWDG peripheral If no problems are encountered on th...

Reviews: