REV04
CAPETTI ELETTRONICA s.r.l. - Strada Stratta 57
10090 CASTIGLIONE TORINESE - TORINO - ITALY
VAT 04837130014 - Phone 011.981.98.11 - Fax 011.981.98.210
e-mail [email protected] - web www.capetti.it
2/6
MWDG-ETH
LAN Configuration Manual
d.
If the upload is successful, the CCS led turns off after few minutes. In case of malfunction the CCS led will
turns in red.
3.
Device Installer.
To know the IP address of the basestation, the management software named “DeviceInstaller”, contained on the
provided setup CD Rom, must be installed;
a.
Connect the PC using the cable to the same LAN of the
MWDG-ETH
. Otherwise, a direct connection between
the PC and the
basestation
can be setup (
using the ethernet cable
);
b.
Install and execute “DeviceInstaller” from Program menu, in the Lantronix directory;
c.
Select the Tools menu
Options and click on the proper network adapter (
typically is named “Local LAN
Connection”
);
d.
Click on “Search” button;
e.
If the search is successful, in the device list will appear an element named “xPico”;
f.
Double click on the element; if a popup with a firewall exception appears, click on “Allow”;
g.
Click on this device the window “Web Configuration” can be selected. On the address bar the IP address of
the module will appear;
h.
Click “send” from theaddress bar. Otherwise is possible to cut and paste this address on the PC browser;
i.
An authentication is requested: if user name and password are not set, leave these fields blank and click on
“OK”;
j.
The “
Web Manager”
management page for ethernet peripherals will opens.