![Capa Energy DWSC302-12 Operating Instructions Manual Download Page 10](http://html.mh-extra.com/html/capa-energy/dwsc302-12/dwsc302-12_operating-instructions-manual_494062010.webp)
High
High
High
High performance
performance
performance
performance wind&solar
wind&solar
wind&solar
wind&solar hybrid
hybrid
hybrid
hybrid controller
controller
controller
controller
9
Work in timed mode, this parameter is
valid.
17
Setting time
2
2-way load output time. 2-way
working at control mode, this
parameter is valid.
12H
√
√
√
√
Note:
Note:
Note:
Note:
1. Modify items that can change this parameter, × that can not be modified, √ that can be modified.
2 .Please do not change parameters if customers do not know too much. Because if set the system inaccurate
may affect the charging efficiency, before you buy this, you’d better give the specific parameters or requirements
of functionality to manufacturers, have factory settings, or call us.
VII.Troubleshooting
Phenomenon
Check the following order
Causes and treatment
Stall fan
1.Check whether the battery is
full the controller
2.Check the brake controller,
manual fan switch
3.Check whether the brake
controller
4.Check the blower output line
between three-terminal
resistance
.
1.If full, then the battery is full
2. If the brake, it will switch to running
3. If the brake, then the fan does not turn
4.If one or more sets of resistance in Europe is less
than 0.4, indicating that the fan cable short-circuit, the
corresponding repair
Can not be
charged
1. Check all cables and terminal
access
2. The long-term no wind, no
sun
3. Check the controller input
terminal voltage of solar
4. Check the wind controller
1.If the cable is bad there is need to overhaul
2.If so, is a normal
3.If the voltage is too low, the cable is damaged or
solar panels is damaged, repair or replace accordingly
4. If the voltage is too low, or three sets of voltage is
not equal, indicating the fan motor windings or faulty
fan output cable, and make the appropriate repair