22
23
5.0 INSTRUCTIONS FOR CANVAC QCLEAN HOSE HANDLE
NOTE:
The Canvac QCLEAN hose and hose handle will only function with a QCLEAN central vacuum system. If you received an
QCLEAN hose and do not have a QCLEAN power unit, please contact your local authorized Canvac dealer to obtain the
proper hose for your central vacuum system.
4.8 Motor fault indicators
If there is a system fault or malfunction with your power unit, the fan blade icon will flash with an exclamation icon. If these
symbols appear on the power unit screen, turn the power unit OFF and call for service. The power unit communicates the
system fault to the QCLEAN hose handle with a RED flashing fan blade.
or
These symbols may appear due to the following faults:
• Maximum system run time
• Electronic problem
• Voltage or current/power surge
• Power unit not responding to electronics
• Motor failure
• Mechanical failure of bag & clogged motor
4.9 Error codes (optional feature on select units)
An error code will appear if your unit requires service from an authorized service technician. The power unit communicates
the system fault to the QCLEAN hose handle with a RED flashing fan blade. Turn OFF the power unit and call for service to
resolve the system alert/error code.
Error Codes:
Er 1: Under current
Er 2: Over current short
Er 3: 30-minute time out
Er 4: Over current long
Er 5: Line error or off current
4.10 Navigation buttons (optional feature on select units)
Below the display screen, are buttons for are Left ( < ); Right ( > ); Enter ( ); and Power ( ).
To modify the Time or reset the Empty Bucket indicator, scroll to the appropriate screen icon and
press the Enter button for 5 seconds. Follow the screen prompts.
4.11 Set Clock on power unit (optional feature on select units)
To set the time, use the left ( < ) or right ( > ) toggle buttons on the power unit to select the clock
and hold the Enter Button ( ) for 5 seconds. Select either 12-hour or 24-hour time format and
set the time using the left ( < ) or right ( > ) toggle buttons, and press Enter ( ) to complete the
sequence.
QCLEAN_CD_2014_Manual_.indd 22