4.2 Power Requirements for the Main Unit and Optional Accessories
Part or Accessory
Power Supply
Power Receptacle Length of Power
Cord
Main Unit (Print Engine Module)
3 Phase
208-240V/30 A outlet
NEMA L15-30R
15’ (4.6 m)
Single Phase
208-240V/50 A outlet
NEMA 14-50R
15’ (4.6 m)
PIM 1
115 V/15 A outlet
NEMA 5-15R
12’ (3.6 m)
PIM 2
115V/15 A outlet
NEMA 5-15R
12’ (3.6 m)
PIM 3
115V/15 A outlet
NEMA 5-15R
12’ (3.6 m)
High Capacity Stacker Only
115V/15 A outlet
NEMA 5-15R
12’ (3.6 m)
High Capacity Stacker with Set
Finisher
115V/15 A outlet
NEMA 5-15R
15’ (4.6 m)
Media Enhancement Module
100-240V/15 A outlet
NEMA 5-15R
12’ (3.6 m)
PRISMAsync Controller
Powered by the Main Unit
—
—
PrintGuard Unit
115V/20 A outlet x 2
NEMA 5-20R x 2
12’ (3.6 m) x 2
GBC PowerPunch
110V/20 A outlet
NEMA 5-20R
12’ (3.6 m) x 2
BLM6200
Single Phase
120V/15 A outlet
NEMA 5-20R
12’ (3.6 m)
BLM6300
Single Phase
120V/15 A outlet
NEMA 5-20R
12’ (3.6 m)
Single Phase
200-240V/20 A outlet
NEMA 6-20R
8’ (2.4 m)
Book Stacker
Powered by the
—
—
BGB3202 Perfect Binder
(Select only ONE outlet
configuration)
3 Phase
208-240 V/30 A outlet
NEMA 14-30R
—
3 Phase
208-240 V/30 A outlet
NEMA L15-30R
—
BGB3202 Compiler
Single Phase
120V/15 A outlet
NEMA 5-15R
—
Videk DocuVision Edge
Single Phase
120V/15 A outlet
NEMA 5-15R
9’ (2.7 m)
Single Phase
220V/15 A outlet
NEMA-6-15R
9’ (2.7 m)
12 Formerly named the BLM200.
31 The Set Finisher is powered by the IIM 208V AC (on the Standard TITAN model only).
32 If the PrintGuard units are installed, the customer must provide two, 115V AC, 20 amp, dedicated, single phase
lines. If a finisher is attached, the customer must supply a separate 208V AC, single phase, 20 amp line.
33 Two outlets are required for a system with one stacker, and three outlets are required for a system with two
stackers.
34 The BGB3202 Perfect Binder can only be configured as a 220 V system.