Chapter 1
2
##0674
[Tx]
at time of V.34 transmission, a shift in procedure from phase 3 and phase 4 to the
control channel and thereafter stops, causing the machine to release the line and
suffer T1 timeout.
##0675
[Rx]
at time of V.34 reception, a shift in procedure from phase 3 and phase 4 to the
control channel and thereafter stops, causing the machine to release the line and
suffer T1 timeout.
##0750
[Tx]
at time of ECM transmission, no meaningful signal is received after transmission of
PPS-NULL, causing the procedural signal to be transmitted more than specified.
##0752
[Tx]
at time of ECM transmission, DCN is received after transmission of PPS-NULL.
##0753
[Tx]
at time of ECM transmission, the procedural signal has been transmitted more than
specified after transmission of PPS-NULL, or T5 time-out (60 sec) has occurred.
##0754
[Tx]
at time of ECM transmission, the procedural signal has been transmitted more than
specified after transmission of PPS-NULL.
##0755
[Tx]
at time of ECM transmission, no meaningful signal is received after transmission of
PPS-MPS, causing the procedural signal to be transmitted more than specified.
##0757
[Tx]
at time of ECM transmission, DCN is received after retransmission of PPS-MPS.
##0758
[Tx]
at time of ECM transmission, the procedural signal has been transmitted more than
specified after transmission of PPS-MPS, or T5 time-out (60 sec) has occurred.
##0759
[Tx]
at time of ECM transmission, the procedural signal has been transmitted more than
specified after transmission of PPS-MPS.
##0760
[Tx]
at time of ECM transmission, no meaningful signal is received after transmission of
PPS-EOM, causing the procedural signal to be transmitted more than specified.
##0762
[Tx]
at time of ECM transmission, DCN is received after transmission of PPS-EOM.
##0763
[Tx]
at time of ECM transmission, the procedural signal has been transmitted more than
specified after transmission of PPS-MPS, or T5 time-out (60 sec) has occurred.
##0764
[Tx]
at time of ECM transmission, the procedural signal has been transmitted more than
specified after transmission of PPS-EOM.
##0765
[Tx]
at time of ECM transmission, no meaningful signal is received after transmission of
PPS-EOP, causing the procedural signal to be transmitted more than specified.
##0767
[Tx]
at time of ECM transmission, DCN is received after transmission of PPS-EOP.
##0768
[Tx]
at time of ECM transmission, the procedural signal has been transmitted more than
specified after transmission of PPS-EOP, or T5 time-out (60 sec) has occurred.
##0769
[Tx]
at time of ECM transmission, the procedural signal has been transmitted more than
specified after transmission of PPS-EOP.
##0770
[Tx]
at time of ECM transmission, no meaningful signal is received after transmission of
EOR-NULL, causing the procedural signal to be transmitted more than specified.
##0772
[Tx]
at time of ECM transmission, DCN is received after transmission of EOR-NULL.
##0773
[Tx]
at time of ECM transmission, the procedural signal has been transmitted more than
specified after transmission of EOR-NULL, or T5 time-out (60 sec) has occurred.
##0774
[Tx]
at time of ECM transmission, ERR is received after transmission of EOR-NULL.
##0775
[Tx]
at time of ECM transmission, no meaningful signal is received after transmission of
EOR-MPS, causing the procedural signal to be transmitted more than specified.
##0777
[Tx]
at time of ECM transmission, DCN is received after transmission of EOR-MPS.
##0778
[Tx]
at time of ECM transmission, the procedural signal has been transmitted more than
specified after transmission EOR-MPS, or T5 time-out (60 sec) has occurred.
##0779
[Tx]
at time of ECM transmission, ERR is received after transmission of EOR-MPS.
##0780
[Tx]
at time of ECM transmission, no meaningful signal is received after transmission of
EOR-EOM, causing the procedural signal to be transmitted more than specified.
##0782
[Tx]
at time of ECM transmission, DCN is received after transmission of EOR-EOM.
##0783
[Tx]
at time of ECM transmission, the procedural signal has been transmitted more than
specified after transmission of EOR-EOM, or T5 time-out (60 sec) has occurred.
##0784
[Tx]
at time of ECM transmission, ERR is received after transmission of EOR-EOM.
##0785
[Tx]
at time of ECM transmission, no meaningful signal is received after transmission of
EOR-EOP, causing the procedural signal to be transmitted more than specified.
##0787
[Tx]
at time of ECM transmission, DCN is received after transmission of EOR-EOP.
##0788
[Tx]
at time of ECM transmission, the procedural signal has been transmitted more than
specified after transmission of EOR-EOP, or T5 time-out (60 sec) has occurred.
##0789
[Tx]
at time of ECM transmission, ERR is received after transmission of EOR-EOP.
##0790
[Rx]
at time of ECM reception, ERR is transmitted after transmission of EOR-Q.
##0791
[Tx/Rx]
while ECM mode procedure is under way, a signal other than a meaningful signal
is received.
##0792
[Rx]
at time of ECM reception, PPS-NULL cannot be detected over partial page
processing.
##0793
[Rx]
at time of ECM reception, no effective frame is received while high-speed signal
reception is under way, thus causing time-out.
##0794
[Tx]
at time of ECM reception, PPR with all 0s is received.
##0795
[Tx/Rx]
a fault has occurred in code processing for communication.