Setting of Bit Switch (SSSW)
Bit Switch Composition
The registration/setup items of the switch are set according to the positions of its 8 bits; the bit switch shown on the display is as
follows, each bit being either 0 or 1:
SW01
0
0
0
0
0
0
0
0
Bit 7
Bit 0
CAUTION:
Do not change service data identified as "not used"; they are set as initial settings.
<1/7>
<READY>
Report
Sssw
Menu Num Ncu Type IP FAX
Print Clear Test
0
0
0
0
0
0
0
0
1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
1
0
0
0
0
0
0
0
SW01
SW02
SW03
SW04
SW05
SW06
0
0
0
0
0
0
0
0
1
0
0
0
0
0
0
0
SW07
SW08
OK
■ SSSW-SW01
Functional Construction
Bit
Function
1
0
0
Error codes for service technician
Output
Do not output
1
Error dump list
Output
Do not output
2
Not used
-
-
3
Not used
-
-
4
Display service error codes in the ##300 series
Display
Do not display
5
Increase the capacity of SUBLOG for USBFAX2
Increase
Do not increase
6
Not used
-
-
7
Cancel prohibition of user setting collectively
Cancel
Do not cancel
Details of Bit 0
Select whether to output service error codes.
When "Output" is selected, service error codes will be on the display and on the report.
Detailed Discussions of Bit 1
Select whether to output error dump list.
When "Output" is selected, the error transmission report and the reception result report at the time of occurrence of an error
are output with the error dump list attached.
Detailed Discussions of Bit 4
Select whether to display service error codes in the ##300 series.
5. Service Mode