4
4
Error Code
Error Code
4-6
4-6
Error Code > Service Error Code
Error Code > Service Error Code
Service Error Code
Code
Cause
Remedy
##3016 [T/R] An instruction of disconnection
(BYE) was received from the network at
an unexpected time.
Perform a communication again.
*1: G3FAX
*2: IPFAX
No.*1 No.*2 T/R
Description
##100 ##3100 [T]
at time of transmission, the procedural signal has been transmitted more than
specified.
##101 ##3101 [T/R] the modem speed does not match that of the other party.
##102 ##3102 [T]
at time of transmission, fall-back cannot be used.
##103 ##3103 [R]
at time of reception, EOL cannot be detected for 5 sec (15 sec if CBT).
##104 ##3104 [T]
at time of transmission, RTN or PIN is received.
##106 ##3106 [R]
at time of reception, the procedural signal is received for 6 sec while in wait
for the signal.
##107 ##3107 [R]
at time of reception, the transmitting party cannot use fall-back.
##109 ##3109 [T]
at time of transmission, a signal other than DIS, DTC, FTT, CFR, or CRP is
received, and the procedural signal has been sent more than specified.
##111 ##3111 [T/R] memory error has occurred.
##114 ##3114 [R]
at time of reception, RTN is transmitted.
##116 ##3116 [T/R] Disconnection of loop current was detected during communication.
##200 ##3200 [R]
at time of reception, no image carrier is detected for 5 sec.
##201 ##3201 [T/R] DCN is received outside the normal parity procedure.
##204 ##3204 [T]
DTC without transmission data is received.
##220 ##3220 [T/R] system error (main program out of control) has occurred.
##223 ##3223 [T/R] while a communication is under way, the line is cut.
##224 ##3224 [T/R] in communication, an error has occurred in the procedural signal.
##226 ##3226 [T/R] the stack printer has fallen outside the RAM area.
##227 ##3227 [R]
An attempt was made to record a file without image.
##229 ##3229 [R]
the recording unit has remained locked for 1 min.
##230 ##3230 [T/R] A unit for controlling the display has malfunctioned.
##231 ##3231 [T/R] A unit for controlling the Control Panel buttons has malfunctioned.
##232 ##3232 [T]
encoding error has occurred.
##237 ##3237 [R]
decoding error has occurred.
##238 ##3238 [R]
the print control unit is out of order.
##261 ##3261 [T/R] system error has occurred.
##280 ##3280 [T]
at time of transmission, the procedural signal has been transmitted more than
specified.
##281 ##3281 [T]
at time of transmission, the procedural signal has been transmitted more than
specified.
##282 ##3282 [T]
at time of transmission, the procedural signal has been transmitted more than
specified.
T-4-2
No.*1 No.*2 T/R
Description
##283 ##3283 [T]
at time of transmission, the procedural signal has been transmitted more than
specified.
##284 ##3284 [T]
at time of transmission, DCN is received after transmission of TCF.
##285 ##3285 [T]
at time of transmission, DCN is received after transmission of EOP.
##286 ##3286 [T]
at time of transmission, DCN is received after transmission of EOM.
##287 ##3287 [T]
at time of transmission DCN is received after transmission of MPS.
##288 ##3288 [T]
after transmission of EOP, a signal other than PIN, PIP, MCF, RTP, or RTN
has been received.
##289 ##3289 [T]
after transmission of EOM, a signal other than PIN, PIP, MCF, RTP, or RTN
has been received.
##290 ##3290 [T]
after transmission of MPS, a signal other than PIN, PIP, MCF, RTP, or RTN
has been received.
##670 ##3670 [T]
at time of V.8 late start, the V.8 ability of DIS front the receiving party is
expected to be detected, and the CI signal is expected to be transmitted in
response; however, the procedure fails to advance, and the line is released
because of T1 time-out.
##671 ##3671 [R]
at time of V.8 arrival, procedure fails to move to phase 2 after detection of CM
signal from caller, causing T1 time-out and releasing line.
##672 ##3672 [T]
at time of V.34 transmission, a shift in procedure from phase 2 to phase 3
and thereafter stops, causing the machine to release the line and suffer T1
timeout.
##673 ##3673 [R]
at time of V.34 reception, a shift in procedure from phase 2 to phase 3 and
thereafter stops, causing the machine to release the line and suffer T1
timeout.
##674 ##3674 [T]
at time of V.34 transmission, a shift in procedure from phase 3 and phase 4 to
the control channel and thereafter stops, causing the machine to release the
line and suffer T1 timeout.
##675 ##3675 [R]
at time of V.34 reception, a shift in procedure from phase 3 and phase 4 to
the control channel and thereafter stops, causing the machine to release the
line and suffer T1 timeout.
##750 ##3750 [T]
at time of ECM transmission, no meaningful signal is received after
transmission of PPS-NULL, causing the procedural signal to be transmitted
more than specified.
##752 ##3752 [T]
at time of ECM transmission, DCN is received after transmission of PPS-
NULL.
##753 ##3753 [T]
at time of ECM transmission, the procedural signal has been transmitted
more than specified after transmission of PPS-NULL, or T5 time-out (60 sec)
has occurred.
##754 ##3754 [T]
at time of ECM transmission, the procedural signal has been transmitted
more than specified after transmission of PPS-NULL.
##755 ##3755 [T]
at time of ECM transmission, no meaningful signal is received after
transmission of PPS-MPS, causing the procedural signal to be transmitted
more than specified.
##757 ##3757 [T]
at time of ECM transmission, DCN is received after retransmission of PPS-
MPS.
Summary of Contents for Super G3 FAX Board-AR1
Page 6: ... Notes Before it Works Serving Safety Precautions ...
Page 8: ...1 1 Product Outline Product Outline Product Outline Specifications ...
Page 10: ...2 2 Technology Technology Technology Basic Construction Controls ...
Page 16: ...4 4 Error Code Error Code Error Code Overview User Error Code Service Error Code ...