COPYRIGHT © 2001 CANON INC.
2000 2000 2000 2000
CANON SmartBase PC1200s/iR1200s REV. 0 DEC. 2001
2-37
CHAPTER 2 USING THE MACHINE
#1 SSSW-SW06: read condition setting
Bit
0
1
2
3
4
5
6
7
Function
not used
not used
not used
No. of remote reception ID digits
not used
not used
not used
not used
1
-
-
-
3digits
-
-
-
-
0
-
-
-
2digits
-
-
-
-
Factory setting
0
Bit
0
1
2
3
4
5
6
7
Function
not used
not used
not used
not used
original read width
not used
not used
not used
1
-
-
-
-
LTR
-
-
-
0
-
-
-
-
A4
-
-
-
Factory setting
1
[Bit 4]
Use it to select a read width for originals.
If ‘LTR’ is selected, the machine will read LTR originals at LTR width (212 mm).
#1 SSSW-SW10: remote control setting
[Bit 3]
Use it to select the number of digits for remote reception IDs; 2 digits or 3 digits.