1.3 Adjustment Procedure
(1) Read the resistance value (
Ω
) at the specified position in the illustration below.
Resistance value indication position
Headunit
(2) Calculate the Voltage value as below.
Note:
The calculation formula differs depending on the identification number indicated on the
head unit.
There are two identification codes, KD27.
Test point
M7
M1
M10
M8
Identification code
MAIN PCB ASS’Y
VR
■
Identification code: KD27
Voltage value =
(Resistance value x 0.0845)
For example, when the resistance value is 3016
Ω
Voltage value =
(3016
Ω
x 0.0845) 15.964V