LV-8235 UST Basic Serial Command Specifications
-19-
7.
Status Read Command
7.1. Format
7.1.1.
PC issues commands in format as below;
“CR” Command [CR]
Command
:
1 character(See Basic Status Read Command Table)
7.1.2. When a projector receives the appropriate command, it returns a character line as the
required data.
Required Data [CR]
Required Data
:
A character line(See Basic Status Read Command Table)
7.1.3.
When the received data cannot be decoded, the projector returns
“?”
[CR]
.
7.2. Transfer Example
Get input mode for projector with basic commands
Command (issues a command of getting current input mode)
PC
→
Projector
“C” “R” “1” “CR”
Projector
→
PC
“1” “CR”
Processing Response
(A few ms
〜
1s)
(
Shows Computer 1 is selected)
7.3. Operation Requirements
Status read Commands are invalid when Eco mode is selected in Standby mode of Setting menu and
projector is in standby.