Sensor
Removing the Delivery
Sensor(PS1)
■ Preparation
1. Remove the machine from the host machine.
“Removing this Machine from the Host Machine” on
page 41
2. Remove the Front Cover Unit.
3. Remove the Rear Cover.
4. Remove the Delivery Tray.
5. Remove the Upper Feed Guide Unit.
Upper Feed Guide Unit” on page 59
6. Remove the Tray Guide Cover.
7. Remove the Staple-free Staple Unit.
Staple-free Staple Unit” on page 65
8. Remove the Processing Tray Unit.
Processing Tray Unit” on page 60
■ Procedure
1. Remove the Delivery Sensor [1].
• 1 Connector [2]
[1]
[2]
1x
Removing the Disengaging
Sensor (PS16)
■ Preparation
1. Remove this machine from the host machine.
“Removing this Machine from the Host Machine” on
page 41
2. Remove the Delivery Tray.
■ Procedure
1. Remove the Disengaging Sensor Holder [1].
• 1 Screw [2]
1x
[1]
[2]
2. Remove the Disengaging Sensor [1].
• 1 Connector [2]
1x
[2]
[1]
4. Parts Replacement and Cleaning
71
Summary of Contents for Inner Finisher-H1
Page 1: ...Revision 3 0 Inner Finisher H1 Service Manual ...
Page 10: ...Product Overview 1 Features 5 Specifications 6 Name of Parts 9 ...
Page 43: ...Periodical Service 3 List of Work for Scheduled Servicing 38 ...
Page 80: ... 3 2 1 4 Parts Replacement and Cleaning 74 ...
Page 97: ...Installation Outline Drawing 1 8 8 6 5 8 2 3 4 7 9 10 11 6 Installation 91 ...
Page 106: ...APPENDICES Service Tools 101 General Circuit Diagram 102 ...