![Canon Inner Finisher-A1 Service Manual Download Page 27](http://html1.mh-extra.com/html/canon/inner-finisher-a1/inner-finisher-a1_service-manual_4040420027.webp)
4
4
4-7
4-7
Parts Replacement and Cleaning Procedure > Main Units > Removing the Gripper Unit
Parts Replacement and Cleaning Procedure > Main Units > Removing the Gripper Unit
Removing the Gripper Unit
1) Remove the upper unit.
"Removing the Upper Unit"(page 4-4)
.
2) Move the stapler rearward.
F-4-12
F-4-12
3) Remove the reuse and.
4) Pull out the gripper unit in the direction of the arrow.
x2
F-4-13
F-4-13
5) Press the lever to remove the gripper unit.
F-4-14
F-4-14