4. Power/Electrical Requirements
The imageRUNNER ADVANCE C9075S PRO requires a NEMA 6-15 receptacle
for the main unit, and NEMA 5-15 receptacle for the PRISMAsync controller.
4.1 Power Requirements for the Main Unit and Optional Accessories
Part or Accessory
Power Supply
Power Supply Cord
/Plug Specifications
Length of
Power Cord
Main Unit
1-208 V/15 A outlet
NEMA 6-15
8’ (2.4 m)
PRISMAsync Controller
w/Operator Panel and
Attention Light
1-120 V/15 A outlet
NEMA 5-15
13.9’ (4.2 m)
Paper Deck Unit-A1
*1
From the main unit
—
—
POD Deck Lite-A1
1-120 V/15 A outlet
NEMA 5-15
8’ (2.4 m)
Multi-Drawer Paper
Deck-A1
1-120 V/15 A outlet
NEMA 5-15
8’ (2.4 m)
Duplex Color Image
Reader Unit-A1
*1
From the main unit
—
—
Document Insertion
Unit-H1
1-120 V/15 A outlet
NEMA 5-15
6’ (1.8 m)
Professional Puncher-
C1 & Professional
Puncher Integration
Unit-B1
*2
1-120 V/15 A outlet
NEMA 5-15
6’ (1.8 m)
Paper Folding Unit-G1
*1
From the finisher
—
—
Inner Booklet
Trimmer-A1
*1
From the finisher
—
—
Puncher Unit-BF1
*1
From the finisher
—
—
Staple Finisher-A1
1-120 V/15 A outlet
NEMA 5-15
6’ (1.8 m)
Booklet Finisher-A1
1-120 V/15 A outlet
NEMA 5-15
6’ (1.8 m)
*1 Does not require any additional outlets.
*2 The Professional Puncher Integration Unit-B1 provides the Professional Puncher-C1 with power.
NEMA 6-15 Receptacle
NEMA 5-15 Receptacle