IMPORTANT
•
We recommend an additional standard 115 V/15 A outlet for service tools, such
as a laptop computer or vacuum that may be used when servicing or configuring
the machine.
•
Use only a dedicated and properly grounded outlet for the main unit. It is also
strongly suggested to use dedicated and properly grounded outlets for each
optional accessory. Do not use extension cords. The ground connection serves
to provide the internal electronics with a reference voltage. Faulty or poor ground
sources will cause this reference voltage to fall into a range that no longer serves
as a reliable reference voltage. The internal logic and programming of the
imagePRESS C910/C810/C710 will not perform reliably because there is an
insufficient difference between the internal operating signal voltages and the poor
ground reference signal. A qualified electrician can measure and provide the
ground source that the imagePRESS C910/C810/C710 or any computer
controlled office equipment requires.
•
Before installation, confirm that all necessary receptacles are available.
•
If the optional Integrated Interface & Stand-A1, which includes a furniture stand,
monitor, keyboard, and mouse, is installed on the imagePRESS Server H350, an
additional 115V/6 A (NEMA 5-15) receptacle is required for the monitor.
•
Step-down transformers are not supported.