![Canon imageCLASS MF200 Series Service Manual Download Page 44](http://html1.mh-extra.com/html/canon/imageclass-mf200-series/imageclass-mf200-series_service-manual_4263294044.webp)
imageCLASS MF200 Series Service Guide for Authorized Servicers
imageCLASS MF200 Series Service Guide for Authorized Servicers
August 2014
Page 39
XI.
Appendix
A. Specifications
Note:
All specifications are for reference purposes only, and are subject to
change without notice.
Table 12 — Machine Specifications
Item
Description
Dimensions (H x W x D)
imageCLASS MF229dw:
Approximately 14.2" x 15.4" x 14.9"
(361 mm x 391 mm x 378 mm)
imageCLASS MF227dw/MF216n:
Approximately 14.2" x 15.4" x 14.6"
(361 mm x 391 mm x 371 mm)
imageCLASS MF212w:
Approximately 12.3” x 15.4” x 14.6”
(312 mm x 391 mm x 371 mm)
Weight
imageCLASS MF229dw:
Approximately 28.9 lb (13 kg)
imageCLASS MF227dw:
Approximately 26.9 lb (12 kg)
imageCLASS MF216n:
Approximately 25.4 lb (11 kg)
imageCLASS MF212w:
Approximately 22.5 lb (10 kg)
Cartridge
Canon Cartridge 137 yields approximately 2,400 LTR pages with
the factory default print density setting.
Cartridge Type
Single cartridge system
Maximum Monthly Print
Volume
imageCLASS MF229dw/MF227dw:
Up to 10,000 prints
imageCLASS MF216n/MF212w:
Up to 8,000 prints
Power Requirements
110V – 127V AC, 50/60 Hz, 15 A
Plug
NEMA 5-15
Power
Consumption
Maximum
Duplex Model: Approximately 1,220 W
Simplex Model: Approximately 1,190 W
Standby Mode
Duplex Model: Approximately 5.8 W
Simplex Model: Approximately 5.4 W
Sleep Mode
Duplex Model:
Wired Connection:
Approximately 1.7 W
Wireless Connection:
Approximately 2.3 W
Simplex Model:
Wired Connection:
Approximately 1.6 W
Wireless Connection:
Approximately 3.2 W
Main Power
Switch Turned
OFF
Approximately 0.5 W
Warm-Up Time
Approximately 13.5 seconds
6
(Temperature: 23°C (73.4°F),
humidity: 65% RH (Relative Humidity); from when the machine is
turned ON using the main power switch to when the Standby
screen is displayed)
Environmental Conditions
Temperature: 50°F to 86°F (10°C to 30°C)
Humidity: 20% to 80% RH (Relative Humidity) (no condensation)
6 Warm-up time may vary, depending on the installation environmental conditions.