4
4
4-127
4-127
Disassembly/Assembly > Pickup Feed System (Duplex Model) > Removing the Pickup Unit (Duplex Model) > Preparation
Disassembly/Assembly > Pickup Feed System (Duplex Model) > Removing the Pickup Unit (Duplex Model) > Preparation
Pickup Feed System (Duplex Model)
Layout Drawing
[3]
[1]
[5]
[2]
[6]
[7]
[4]
No.
Name
Reference
Remarks
[1] Delivery Slave Roller Unit
[2] Pickup Unit
[3] Duplex Solenoid
[4] Pickup Tray Unit
[5] Separation Pad
[6] Pickup Roller
[7] Pickup Solenoid
F-4-362
T-4-45
Removing the Pickup Unit (Duplex Model)
■
Preparation
1) Remove the Left Cover (Duplex Model) (Refer to page 4-86).
2-1) Remove the DADF Unit + Reader Unit (DADF Model) (Refer to page 4-27).
2-2) Remove the SADF Unit + Reader Unit (SADF Model) (Refer to page 4-51).
2-3) Remove the Copyboard Cover + Reader Unit (Copyboard Model) (Refer to page 4-76).
3) Remove the Right Cover (Duplex Model) (Refer to page 4-87).
4) Remove the Front Cover Unit (Duplex Model) (Refer to page 4-89).
5) Remove the Upper Cover Unit (Duplex Model) (Refer to page 4-89).
6) Remove the Duplex Feed Guide Unit (Duplex Model) (Refer to page 4-91).
7) Remove the Main Controller PCB (Duplex Model) (Refer to page 4-95).
8) Remove the FAX NCU PCB (FAX Model 120/230V) (Duplex Model) (Refer to page 4-107).
9) Remove the Edge Left Cooling Fan (Duplex Model) (Refer to page 4-99).
10) Remove the Separation Pad (Duplex Model) (Refer to page 4-135).
F-4-363