DC10 E, DC20 E
SERVICE MODE / ADJUSTMENT
17
5-2-3 Preparation for CCD Image Adjustment (1)
For this adjustment, use the same conditions as those specified in 5-2-2 Iris Adjustment (Coarse Adjustment)
SPEC.
Manual adjustment
Preparation)
(1) On the CCD image adjusting tool, mount its light source part. Turn on power to the CCD image adjusting tool.
Procedure)
(1) According to the table shown below, adjust the light quantity of the CCD image adjusting tool.
Note)
If step 1 is not taken, the result of CCD image adjustment may become NG. To avoid this, be sure to carry out step 1.
Fig. 14
R
G
B
ST EP PROCEDURE
Microcomputer operation
PREPARAT ION
CS
Function MD ADDR
DT
1
1) Make the setting shown at right.
0
7
ST
0000
01
2) Perform storing.
↑
↑
RD
↑
01
V synchronization set
(press the PAUSE button.)
(DT becomes 00 after storing.)
2
1) Make the setting shown at right.
2
08
ST
301A
01
2) Perform storing.
↑
↑
RD
↑
↑
T ool light intensity adjustment mode
(press the PAUSE button.)
3
4
1) Make the setting shown at right.
2
08
ST
301A
00
2) Perform storing.
↑
↑
RD
↑
↑
Move to normal mode.
(press the PAUSE button.)
MONIT OR
T urn the light intensity adjusting knob of the tool so that each of the R, G and B data shown in Figure 14 will be 80±10.