Chapter 5
5-3
5.3
Service Error Code
5.3.1
Error Code List
0006-6074
T-5-3
Code
Detail
code
Description
Type
Remedy
E400
0001
DF
communicati
on error
Check sum error
Disconnect and then
connect the connector.
Replace the reader
controller PCB. Replace
the ADF controller PCB.
0002
Reception status
error
Disconnect and then
connect the connector.
Replace the reader
controller PCB. Replace
the ADF controller PCB.
0003
Reception
interrupt error
Disconnect and then
connect the connector.
Replace the reader
controller PCB. Replace
the ADF controller PCB.
E490
0001
Wrong DF
The installed DF is
not of a supported
type.
Install an ADF that is
compatible with the
machine.