Chapter 5
5-1
5.1
Overview
5.1.1
Overview
0006-2368
The CPU on the machine's ADF controller PCB is equipped with a mechanism to run a self
check, which will flash the Original Placement indicator upon detection of a fault and
communicate to the host machine by means of code. The communication may be any of the
following 3 types, each causing the Original Placement indicator to flash in its own way:
T-5-1
The code used for an alarm and jam may also be checked using the service mode of the host
machine; in the presence of an error, the displays f the host machine will indicate a specific
error code:
F-5-1
Error type
Original Placement indicator
Alarm
flashes at intervals of 240 msec
Jam
flashes at intervals of 160 msec
Error
flashes at intervals of 80 msec
Jam code; see descriptions for jam code list.
The notation [1] stands for a jam
occurring inside the machine.