2
2
2-77
2-77
Technical Explanation > Embedded RDS > E-RDS Setup > Confirmation and preparation in advance
Technical Explanation > Embedded RDS > E-RDS Setup > Confirmation and preparation in advance
E-RDS Setup
■
Confirmation and preparation in advance
To monitor a device with e-Maintenance/ imageWARE Remote, the following settings are
required.
(1) Advance confirmation
Confirm with the UGW administrator that the device to be monitored with e-Maintenance/
imageWARE Remote is registered in the UGW.
(2) Advance preparations
Interview the user’s system administrator in advance to find out the following information
about the network.
Information item 1
IP address settings
• Automatic setting : DHCP, RARP, BOOTP
• Manual setting : IP address, subnet mask and gateway address to be set
Information item 2
Is there a DNS server in use?
If there is a DNS server in use, find out the following.
• Primary DNS server address
• Secondary DNS server address
Information item 3
Is there a proxy server?
If there is a proxy server in use, find out the following.
• Proxy server address
• Port No. for proxy server
Information item 4
Is proxy server authentication required?
If proxy server authentication is required, find out the following.
• User name and password required for proxy authentication
(3) Network settings
Based on the results of the information obtained in (2) Advance preparations, make the
device network related settings in accordance with the following procedures.
1) Displaying the Additional Functions screen
1. Touch the [Additional Functions (User Mode)] button.
2. When a system management department ID and system management password are
set up, enter the System Manager ID and System Password to perform a log-in.
2) Setting IP address-related items
1. Touch the [System Settings] > [Network Settings] > [TCP/IP Settings] > [IPv4 Settings]
> [IP Address Settings] buttons.
2. Set the IP address based on the result obtained in “(2) Advance preparations -
• For automatic acquisition, select from [DHCP], [RARP], [BOOTP].
• For manual setting, set the IP address, subnet mask and gateway address.
F-2-110
F-2-111
Summary of Contents for 1730
Page 12: ...Update Firmware XXV Volume Control XXV Backup Data XXVI ...
Page 17: ...1 1 Product Overview Product Overview Product Lineup Features Specifications Parts Name ...
Page 235: ...7 7 Error Code Error Code Overview Error Code Jam Code Alarm Code ...
Page 250: ...8 8 Service Mode Service Mode Outline Details of Service Mode ...
Page 333: ... Service Tools General Timing Chart General Circuit Diagram List of User Mode Appendix ...