EdgeAccess Universal Chassis System
Model 9135 10/100/1000
2-1
Chapter 2
Setup and Installation
This section describes how to install the 9135 and the interface modules.
Caution
Equipment intended only for installation in a RESTRICTED ACCESS LOCATION
accessible only to electrically skilled persons and electrically instructed persons with
the proper authorization.
2.1
Install the 9135
The 9135 is tested and inspected before shipment from the factory. If there is obvious damage to the
shipping container, contact the carrier immediately.
Caution:
Follow electrostatic discharge (ESD) safety precautions when handling Canoga
Perkins products, as with all electronic devices with static sensitive components.
1. Unpack the 9135. Keep the shipping container until the unit is installed and fully operational. In
the unlikely event that the unit is defective, contact Canoga Perkins Customer Service for a return
authorization number (RMA) and instructions on return shipment. For details, see Appendix A.
2. On the UTP copper interface (9100-330), set SW1 for your system; see Figure 2 and Table 1.
SW1
Figure 2. SW1 on UTP Copper Interface
Table 1. SW1 Settings, UTP Copper Interface
Switch
Name
On
Off
1-1
10 or 100 Mbps 100 Mbps
10 Mbps
1-2
FDX
Full-duplex
Half-duplex
1-3
AUT (Auto
negotiation)
Manages the fastest common operating mode
between this module and its link partner
Follow SW1-1 and 1-2
settings
1-4
LLF
Enable Link Loss Forward (LLF)
Disable LLF
Summary of Contents for EdgeAccess 9135 SNMP
Page 1: ...Model 9135 SNMP Managed 10 100 1000 Ethernet Switch User Manual...
Page 2: ......
Page 8: ...EdgeAccess Universal Chassis System Model 9135 10 100 1000 vi...
Page 16: ...EdgeAccess Universal Chassis System Model 9135 10 100 1000 2 6...
Page 40: ...EdgeAccess Universal Chassis System Model 9135 10 100 1000 3 24...
Page 50: ...EdgeAccess Universal Chassis System Model 9135 10 100 1000 5 8...