9
Gas type:
Natural or Propane gas, as indicated
on data label
Gas consumption:
26 MJ/hr input
Energy star rating:
3.77
Energy output:
20.7 MJ/hr
Heater type:
Heater approved to AG 103.
Operating pressure:
Natural gas: 1.0 kPa
Propane gas: 2.65 kPa
Min. inlet pressure:
1.20 kPa (NG)
For Propane gas regulated to supply
2.65 kPa
Gas regulator:
Integral with controller
Fan:
Three speed
Controller:
Electronic
Power requirement:
240 VAC 10 A
Optional Accessories:
• Safety guard
• Gold or silver trim
• Glass front
• Cathedral ceiling flue box
Flue kit:
3 x 900mm lengths of 125mm ø
painted flue.
1 x 900mm length of 125mm ø
plain flue.
1 x ceiling ring.
1 x 900mm painted bottom flue
spigot length.
Overall dimensions:
Refer fig. 8.
Heater Specifications
8
16
This heater is a flued appliance. It must be properly connected to a
flue system in accordance with the latest edition of the Gas Installa-
tion Code, AS 5601/AG 601.
If elbows are needed, the total horizontal length depends on the
number of elbows used. Venting should never slope down. A 6mm
per 500mm horizontal rise is recommended.
If practical locate the heater in a position to minimise the use of
horizontals and elbows.
The flue rise should be a minimum of 1.8m before any horizontal
run is used.
If placed against a combustible wall the 40mm rear spacers locate
against the wall.
1. Ensure clearances to combustible have been observed. For clear-
ances refer page 10.
2. The centre line of the flue is 120mm to rear of appliance (includ-
ing rear spacers).
3. Carry out installation as per figure 26 (ceiling plate installation)
and figure 27 (flue installation).
Cut a hole 180mm ø in the ceiling in line with the flue position.
Secure ceiling plate against the ceiling by bending out the tabs
above the ceiling.
Note: If the ceiling has an incline, the ceiling box will need to
be fitted. Installation instructions are supplied with the ceiling
box.
The flue kit contains:
3 x 900mm lengths of 125mm ø painted flue.
1 x 900mm length of 125mm ø plain flue.
1 x ceiling plate
1 x 900mm painted bottom flue spigot.
20
26
Flue installation
Flue kit
Summary of Contents for Fitzroy
Page 17: ...17 27 ...
Page 22: ...22 Notes ...
Page 23: ...23 Notes ...
Page 24: ...F IN Part No F2774 Revision C Cannon FITZROY PROFILE ...