7
5. To increase the fan speed to MED, press switch for MED setting. Refer
figure 5.
6. To increase the fan speed to HIGH, press switch for HIGH setting.
Refer figure 6.
7. To turn the burner to LOW setting, press switch for LOW setting. Refer
figure 7.
On low burner setting it is more efficient to operate the fan speed on
LOW.
8. If the burner fails to ignite, wait 20 seconds and repeat the ignition
procedure. Refer figure 8.
To turn burner OFF
To turn burner ON
9. In case of power failure return the switches to the OFF setting (refer
figure 2). When the power returns wait 20 seconds for any unburnt gas
to vent and start re-ignitions as per point 3.
5
6
7
8
18
pressure to 0.75 kPa for Natural gas or 2.65 kPa for LPG. (Turn clock-
wise to increase pressure and anticlockwise to decrease pressure).
26. Switch the heat button back to “Low Flame’ position as indicated in
figure 36(a),
retain spanner in position
and using a screwdriver as
per figure 36(b) adjust the central screw control to give a pressure
reading of 0.3 kPa for Natural Gas and 1.1 kPa for LPG. (Turn clock-
wise to increase pressure and anticlockwise to decrease pressure).
27. Switch burners off and remove the manometer tube. Tighten pressure
test point by turning the captive screw fully clockwise.
Replace plastic cap. Ensure the little lug is positioned towards lower
right hand side to clear the control.
28. Refit the lower front cover, making sure not to damage the power cord.
29. Follow User Instructions to turn on heater.
Operate the heater on HIGH and LOW burner and all fan speeds.
The flame should be stable, no lifting from the burner and the logs
should glow after approximately 15 minutes of operation at HIGH
burner.
If the flame is unstable:
❍
Check that the burner is located correctly.
❍
Check that the glass front is located correctly and is against the
sealing rope.
❍
Check that the gas pressure is correctly adjusted.
If the heater still does not operate to specification refer to the trouble-
shooting chart on pages 20 & 21, or contact Sampford IXL in your
state.
36
35