7

5. To increase the fan speed to MED, press switch for MED setting. Refer

figure 5.

6. To increase the fan speed to HIGH, press switch for HIGH setting.

Refer figure 6.

7. To turn the burner to LOW setting, press switch for LOW setting. Refer

figure 7.

On low burner setting it is more efficient to operate the fan speed on

LOW.

8. If the burner fails to ignite, wait 20 seconds and repeat the ignition

procedure. See below.

To turn burner OFF

To turn burner ON

    

9. In case of power failure return the switches to the OFF setting (refer

figure 2). When the power returns wait 20 seconds for any unburnt

gas to vent and start re-ignition as per point 3.

5

6

7

18

Alternative double skin flue installation

This heater is a flued appliance. It must be properly connected to a flue

system in accordance with the latest edition of the Gas Installation Code,

AS 5601.

If elbows are required, we recommend 45

°

 only and no more than two in

the total flue run. There should also be a minimum of 250mm straight flue

section in between bends.

If practical locate the heater in a position to minimise the need for elbows.

There must be at least 1.8m of vertical before any changes in direction of

flue.

1. Ensure clearances to combustible have been observed. For clearances

refer page 10.

2. The centre line of the flue is 120mm to rear of appliance (excl. rear

spacers).

3. Carry out installation as per figure 27 (ceiling plate installation) and

figures 28 & 29 (flue installation).

Cut a hole 195 x 185mm in the ceiling in line with the flue position.

4. One large and two small holes in the bottom end of the lower outer flue

cover locate around the flue spigot and two locating pins. Refer figure
30.

Note: If the ceiling has an incline, the ceiling box will need to be fitted. The

ceiling box is an accessory and can be ordered from the supplier. Instal-

lation instructions are supplied with the ceiling box.

Alternative flue kit

The flue kit contains:

4 x 900mm lengths of 75mm ø inner galvanised flue.
1 x 850mm length of 170mm wide lower outer flue cover.
2 x 850mm length of 170mm wide upper flue cover.
1 x ceiling plate.
1 x 75mm AGA approved flue cowl.

Flue installation - Alternative double skin flue kit

27

Summary of Contents for Canterbury CANTFS-03-LP

Page 1: ...heater is approved for use with Natural and Propane gases Please leave instructions with the owner USER INSTRUCTIONS INSTALLATION INSTRUCTIONS SERVICE INSTRUCTIONS FREESTANDING MODELS CANTFS 03 NG CA...

Page 2: ...on Log installation Gas control Gas pressure point Installation tips Flue installation Standard flue kit 16 17 Flue kit Alternative double skin flue installation 18 19 Alternative flue kit Service ins...

Page 3: ...with manufacturer s instruc tions this warranty may be void The customer must keep their Tax Invoice as proof of purchase of this product and compliance certificate as proof of required installation M...

Page 4: ...e and other flammable liquids Do not place clothing or other flammable material on or near the heater 4 Keep curtains clothing furniture and other flammable materials at least 900mm from front rear an...

Page 5: ...ter a few hours use at the maximum control position 13 Testing the effectiveness of the flue Before testing the flue confirm air vents are unobstructed If an exhaust fan or other heating appliances ar...

Page 6: ...ol lay out refer to figure 2 3 To turn heater on press switch to POWER ON position There is a 5 second delay before the burner ignites At this setting the burner is on LOW and the fan speed is on LOW...

Page 7: ...setting Refer figure 7 On low burner setting it is more efficient to operate the fan speed on LOW 8 If the burner fails to ignite wait 20 seconds and repeat the ignition procedure See below To turn b...

Page 8: ...h a lint free damp cloth Any stubborn stains can be removed with a non abrasive spray on cleaner If an abrasive cleaner is used the paint finish will be damaged Internally the heater should only be cl...

Page 9: ...p Power consumption 90 VA maximum Optional Accessories Safety guard Gold trim Cathedral ceiling flue box for standard flue only Standard flue kit 2 x 900mm lengths of 125mm painted upper flue 1 x 900m...

Page 10: ...3 4 on page 4 For minimum clearances refer fig 9 and 10 4 Remove the carton from the heater and lift from pallet Check that the heater is suitable for the gas available Refer to the data label locate...

Page 11: ...r of appliance For inlet position see figure 13 Log installation 11 The burner is contained within the burner chamber Refer figure 14 12 Carefully unpack the log set Logs are numbered as follows No 1...

Page 12: ...ace log No 4 on single right back pin ensure left side of log rests on depression in No 3 log Refer figure 18 13 Refit the inner glass but do not overtighten the screws 14 Refit the front glass surrou...

Page 13: ...on and Burner low flame are factory set however if pressures need to be checked or adjusted follow the procedures described below and on the next two pages 16 To check control outlet pressure at burn...

Page 14: ...ontrol 21 Refit the lower front cover making sure not to damage the power cord 22 Follow User Instructions to turn on heater and test for correct operation before leaving 23 The heater flames should b...

Page 15: ...ment on 1300 727 421 if the installation is unusual or you have any concerns with the installation and or heater operation before the installation commences Any service request resulting from incorrec...

Page 16: ...een observed For clearances refer page 10 2 The centre line of the flue is 120mm to rear of appliance including rear spacers 3 Carry out installation as per figure 25 ceiling plate installation and fi...

Page 17: ...17 26 Flue installation Standard flue kit...

Page 18: ...of appliance excl rear spacers 3 Carry out installation as per figure 27 ceiling plate installation and figures 28 29 flue installation Cut a hole 195 x 185mm in the ceiling in line with the flue posi...

Page 19: ...19 28 29 30 Flue installation Alternative double skin flue kit...

Page 20: ...ng screws adja cent to the gas inlet at the rear of the appli ance releasing the control 4 Replace in reverse order To replace the fan 1 Disconnect the fan from the fan plug 2 Undo the two M5 wing nut...

Page 21: ...o this appliance For service to this appliance or spare parts please contact the CANNON distributer Sampford IXL 52 70 Sparks Avenue Fairfield Vic 3078 Phone 1300 727 421 Fax 1300 727 425 email servic...

Page 22: ...wire into the 8 way switch connector will be energised as soon as the flame has been sensed 5 Confirm spark is produced A blue spark can be seen when the heater ignition when heater is turned on proc...

Page 23: ...than 1 5 micro amps at all times Take precaution because the ionisation probe can have a high negative voltage and can cause shock 11 Fuse blowing If the fuse continues to blow check the solenoid coi...