background image

-When after drinking,it is recommended to last after 20 minutes ,it

is because 20 minutes is approximately for alcohol to be absorbed

into blood from the digestive organs,and residual alcohol

remaining in the mouth takes this long to dissipate:

--For accurate result,do not repeat next testing with in 3 minutes

after last time.

--Do not smoke and eat for 20 minutes prior testing.

--Do not use chemicals to clean the tester directly.

--Do not blowing liquid into the breath pipe.

--Do not use any excitant substances near the tester,such as

paint,insecticides,alcohol.

--Do not place the tester in the closed environment with

contaminated air.

--Modifying or tampering with the unit’s internal components may

cause a malfunction.

--The unit is designed to be used as an aid to promote reasonable

driving,It should not,be used in anticipation of the use or operation

of vehicles,machinery,or equipment. The unit makes no

references whatsoever to blood alcohol content or other such

measures of intoxication promulgated by government,medical or

other agencies or bodies.

Notes

1.Regardless of whether the product is used,manufacturers and

vendors will not bear any responsibility for the violations,for

example: drunk driving and high-altitude operations.

2.Each person reacts differently to alcohol, so the test results are

for reference only, which cannot serve as the criteria in

determining the outcome.

6. COMMON FAULTS AND SOLUTIONS

Summary of Contents for AD3000

Page 1: ...LCOHOL TESTER CT3404 Ref no AD3000 USER MANUAL SAVE THESE INSTRUCTIONS AND PRECAUTIONS READ ALL PRECAUTONS AND INSTRUCTIONS BEFORE USE Cannon Tools Limited Address 20 Station Road Rowley Regis West Midlands B65 0JU U K ...

Page 2: ......

Page 3: ...ign and type as brought into circulation by us In case of alteration of the machine not agreed upon by us this declaration will lose its validity Product description DIGITAL BREATH ALCOHOL TESTER Model CT3404 Ref no AD3000 Applicable EC Directives EMC Directive 2014 30 EU Harmonized standards EN 61326 1 2013 20 Station Road Rowley Regis West Midlands B65 0JU U K Mr Gurcharan Tony Singh Sanghera Ma...

Page 4: ... 9 g l 3 Quick response and resume 4 Auto power off 5 Use mouthpiece 6 Key chain 7 Use 2 AAA alkaline batteries Reference BAC Blood Alcohol Concentration 0 05 Bac refers to there is 0 05g alcohol in each 100ml of blood 2 IMPORTANT INSTRUCTIONS DO NOT DRIVE AFTER DRINKING ALCOHOL We can t emphasize enough how dangerous it is for you to drink and drive Your vision and your brain are the most importa...

Page 5: ...es on your breath such as diabetes or low calorie intake may cause false results This test and your test result cannot be held as juridical proof in case of law encounters The BAC results are for reference only and the test results cannot be used as a tool to determinate whether you should operate a vehicle or not The manufacturer distributer and importer disclaims any legal responsibility for the...

Page 6: ... LCD will turn on with one beep sound 2 The warm up symbol is displayed and the 10 to 00 countdown is started that indicate the tester is in warm up mode Note It always has a large number of gas impurity adsorbed on the surface of alcohol tester when first time taking out the tester from the packaging or after long time no using for the tester it need more time for cleaning and warm up the sensor ...

Page 7: ...t from the alcohol tester LCD 4 The Caution symbol is displayed if the alcohol concentration is the level 0 02 BAC or 0 2g I to 0 05 BAC or 0 5g l 0 05 BAC or 0 5g I to 0 08 BAC or 0 8g l 5 The Danger symbol is displayed with beep audible alert if the alcohol concentration is the level Over equal 0 05 BAC or 0 5g l Over equal 0 08 BAC or 0 8g l 6 If no blow into the breath inhaler at the test mode...

Page 8: ... the alcohol tester be turned off Replace mouthpiece 1 Contrarotate once the mouthpiece will be loosened 2 Replace the new mouthpiece on the right place clockwise rotation it will be OK Backlight when the tester is turned on the LCD backlight will light until tester auto power off Replace battery The LCD filckering indicates low power of batteries please replace 2 AAA alkaline batteries 5 PRECAUTI...

Page 9: ...t with contaminated air Modifying or tampering with the unit s internal components may cause a malfunction The unit is designed to be used as an aid to promote reasonable driving It should not be used in anticipation of the use or operation of vehicles machinery or equipment The unit makes no references whatsoever to blood alcohol content or other such measures of intoxication promulgated by gover...

Page 10: ...ies incorrectly Installing batteries in correct polarity Very low power batteries Replacing the new alkaline batteries Circuit Fault Contacting after sale service Blowing no response Warm up not completing Warm up for more time Circuit Fault Contacting after sale service Blowing no result Residual gas in tester Warm up again Not blowing in Schedule time Blowing during BLOW countdown time No blowin...

Page 11: ...00 5 0 05 0 5 0 5 50 0 25 125 6 0 06 0 6 0 6 60 0 30 150 7 0 07 0 7 0 7 70 0 35 175 8 0 08 0 8 0 8 80 0 40 200 9 0 09 0 9 0 9 90 0 45 225 10 0 10 1 0 1 0 100 0 50 250 11 0 11 1 1 1 1 110 0 55 275 12 0 12 1 2 1 2 120 0 60 300 13 0 13 1 3 1 3 130 0 65 325 14 0 14 1 4 1 4 140 0 70 350 15 0 15 1 5 1 5 150 0 75 375 16 0 16 1 6 1 6 160 0 80 400 17 0 17 1 7 1 7 170 0 85 425 18 0 18 1 8 1 8 180 0 90 450 1...

Page 12: ...CANNON TOOLS LTD Add 20 station road Rowley Regis west midlands B65 0JU U K Made in China ...

Reviews: