background image

1

 

Index

 

 
Installation............................................ 2 
Comment .............................................. 3 
Frequency Question............................ 7 
 
Interface................................................ 9 
Keyboard .............................................. 10 
RS-232C................................................ 12 
Wand Emulation .................................. 14 
OCIA...................................................... 15 
 
System Control .................................... 16 
 
UPC-A ................................................... 19 
UPC-E ................................................... 20 
EAN-13.................................................. 21 
EAN-8 .................................................... 22 
Code-39 ................................................ 23 
Interleaved 2 of 5 ................................. 24 
Industrial 2 of 5 .................................... 25 
Matrix 2 of 5.......................................... 26 
Codabar/NW7 ....................................... 27 
Code-128 .............................................. 29 
Code-93 ................................................ 30 
Code-11................................................. 31 
MSI/Plessey.......................................... 32 
 
Preamble/Postamble ........................... 33 
 
Appendix .............................................. 34 
 
ASCII Code Table................................. 35 
Hexdecimal/Decimal Table ................. 36 
 
 

 

Installation 

2

 

 

Installation 

 

1) First of all, you must make sure that the power is 

disconnected form your equipment before connecting 

the scanner. Beside, you also have to check the 

cable connector of the scanner match your 

equipment interface correctly. 

2) Boot up your computer after connecting the scanner 

with your equipment, the scanner will make a long 

music and light the LED, above scanner to indicate a 

successful power on. Trigger the button, the scan 

line in front of scanner will active. Now you can start 

to set programming optimal usage. 

 

Recommened Steps 

 

 

W

hen the required settings have been configured, 

all settings are stored in non volatile memory of scanner 

after reading 

EXIT

 

label. There are recommended steps 

as follows. 

 

1) Set right interface of scanner for your host at 

9. 

  First time, you may ignore it unless you want to 

change the scanner into other interface usage. 

2) Set interface protocol to optimize of scanner with 

your host. 

3) Set system control of scanner, such as specific 

adjustments, indicator, scanning mode, code ID and 

code name transmission which you prefer usage in 

system Control at 

16. 

4) Set code option of scanner for your usage. You must 

make sure to enable the symbology first, then 

Min./Max. code length, code ID, checksum and 

truncate digits are also convered. 

5) Set string format of the scanner, such as preamble, 

postamble, prefix, suffix, for your application at 

33. 

 

Summary of Contents for CM-880

Page 1: ...e pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interface when the equipment is operated in a commercial environment This equipment ge...

Page 2: ...icate a successful power on Trigger the button the scan line in front of scanner will active Now you can start to set programming optimal usage Recommened Steps When the required settings have been co...

Page 3: ...e will be used for shorter barcode data output or multi field scanning Comment 4 Response Delay Set value The time out is a pre defined delay time for serial communication of scanner to wait for hands...

Page 4: ...ed Therefore it can not read the WPC barcode without ADD ON It is recommended to program the ADD ON to be enabled while the ADD ON code must be read out Expansion The expansion of function is used onl...

Page 5: ...equipment See 11 Please contact with your dealer if scanner dose not work properly Frequent Question 8 Q If scanner dosen t need an Enter character addition after each barcode label transmission A Ref...

Page 6: ...indicated by Keyboard Wedge 10 EXIT EXT Keyboard Type DFA DFB IBM AT PS 2 DFA DFB IBM XT DFC DFD Macintosh ADB DFC DFD IBM PS 2 25 30 DFE DFF NEC 9801 DFE DFF IBM PS 2 55 DFG DFH IBM 5550 DFG DFH KT...

Page 7: ...ish SV DGI DGJ Switzerland SF DGK DGL UK UK DGK DGL Spare Specific Adjustments BAL BAM Inter char Delay 00 99 1ms BAL BAM Transmit Delay 00 99 10ms RS 232C 12 EXIT EXT Handshaking Protocol DLA DLB Non...

Page 8: ...and Emulation 14 EXIT EXT Active Level DMA DMB Bar High DMA DMB Space High Normal Level DNA DNB Low DNA DNB High Output Speed DOA DOB Low DOA DOB Medium DOC DOD High DOC DOD Turbo Narrow Wide Ratio DQ...

Page 9: ...AM System Control 16 EXIT EXT Power on Music CBA CBB Disable CBA CBB Enable Power on Auto Trigger CCA CCB Disable CCA CCB Enable Good read LED CDA CDB Disable CDA CDB Enable Good read Beep CEA CEB Dis...

Page 10: ...nsmission IKA IKB Disable IKA IKB Enable Code Name Transmission IJA IJB Disable IJA IJB Enable System Control 18 EXIT EXT Money Testing IOA IOB None IOA IOB Right Bottom IOC Left Bottom IOC Specific A...

Page 11: ...e Leading 00 15 BAO BAP Truncate Ending 00 15 AAA Code ID ASCII AAA UPC E 20 Code Read ECA ECB Disable ECA ECB Enable Add on Read EDA EDB Disable EDA EDB Add on 2 Only EDC EDD Add on 5 Only EDC EDD Ad...

Page 12: ...Adjustments BAS BAT Truncate Leading 00 15 BAS BAT Truncate Ending 00 15 AAD Code ID0 ASCII AAD EAN 8 22 Code Read ESA ESB Disable ESA ESB Enable Add on Read ETA ETB Disable ETA ETB Add on 2 Only ETC...

Page 13: ...e Specific Adjustments BAY BAZ Truncate Leading 00 15 BAY BAZ Truncate Ending 00 15 BAW BAX Min Code Length 00 48 BAW BAX Max Code Length 00 48 AAG Code ID ASCII AAG Interleaved 2 of 5 24 Code Read FK...

Page 14: ...Truncate Ending 00 15 BBE BBF Min Code Length 00 48 BBE BBF Max Code Length 00 48 AAI Code ID ASCII AAI Matrix 2 of 5 26 Code Read FVA FVB Disable FVA FVB Enable Checksum Verification FXA FXB Disable...

Page 15: ...r GHA GHB Disable GHA GHB Enable Start End Transmission GIA GIB Disable GIA GIB Enable Checksum Verification GJA GJB Disable GJA GJB Enable Checksum Transmission GKA GKB Disable GKA GKB Enable Codabar...

Page 16: ...e Leading 00 15 BBW BBX Truncate Ending 00 15 BBU BBV Min Code Length 00 48 BBU BBV Min Code Length 00 48 AAM ABK Code ID ASCII AAM ABK Concatenation Code ASCII Code 93 30 Code Read GTA GTB Disable GT...

Page 17: ...justments BCE BCF Truncate Leading 00 15 BCE BCF Truncate Ending 00 15 AAO Code ID ASCII AAO MSI Plessey 32 Code Read HEA HEB Disable HEA HEB Enable Checksum Verification HGA HGB Disable HGA HGB Mod 1...

Page 18: ...e Transmission IFA IFB Disable IFA IFB Enable Postamble Data ABB ABC Data0 ASCII ABB ABC Data1 ASCII Prefix Transmission IGA IGB Disable IGA IGB Enable IMA Clear All Data IMA Prefix Data ABF 15 Bytes...

Page 19: ...F FS D Enter F12 CR GS E Insert Ctrl SO RS F Delete Alt SI US For keyboard wedge only L H 2 3 4 5 6 7 0 SP 0 P p 1 1 A Q a q 2 2 B R b r 3 3 C S c s 4 4 D T d t 5 5 E U e u 6 6 F V f v 7 7 G W g w 8 8...

Reviews: