Page 2
2.3 Battery Charger Operation
Connect the power supply unit to the socket found on the side of the charger case and connect the power
supply unit to a mains supply. When plugged in, the 3 status LEDs at the front of the charger will first turn
AMBER, then they will turn off one after another and finally simultaneously flash GREEN.
The charger is then ready to be used.
Place the batteries in the charger (gold contact side down).When the battery has been detected, the
corresponding LED turns RED. If the LED does not turn RED, please check that the battery has been
correctly positioned (gold contact side down at the back of the compartment).
Charging duration is approximately 5 hours for a 2600mAh battery. Once the battery is fully charged, the
corresponding LED turns GREEN.
A battery can be left in the charger - even after it has been completely charged.
2.4 LED Indicators
Steady RED
Charging.
Steady GREEN
Battery charged.
Flashing RED
Battery defect, charge has stopped, replace the battery.
Flashing GREEN
No battery installed.
Flashing GREEN and RED alternating
Battery temperature is outside of the authorised range,
charging is suspended until the correct temperature has
been reached.
Flashing ORANGE
Unrecognised battery, check the battery type.
Two 3-way chargers can be connected together, to charge up to 6 batteries simultaneously.
Only one PSU is required.
Place the chargers on a flat surface, front charging bays facing you. Connect the charging bays together – the
magnet system will hold the chargers together.
2.5 Battery Charger Specification
2.6 Connecting Two Chargers Together
2.7 Accessories
AC/DC power unit
electrical supply
100 - 240VAC ~ 1.5A
50 to 60Hz
Operating Temperature
5 deg C to 45 deg C
Charge Duration
5 hours
(2600mAh battery)
Dimensions
Battery Lifetime
L: 143mm H:39mm W: 75m
> 500 cycles