INSTALLATION
Instructions for the installer
The Purchaser is responsible for the installation of the hob. The Manufacturer does not
accept any responsibility for any damage or loss resulting from incorrect installation,
and as such this will not covered by the Manufacturer’s Guarantee.
The hob may be installed in any worktop which is heat resistant to a temperature of
100° C, and has a thickness of 25 - 40 mm. The dimensions of the insert to be cut out
of the worktop are in shown in Fig. 1.
If the Hob is fitted next to a cabinet on either side,
the distance between the Hob and the cabinet
must be at least 150 mm (see Fig. 2); while the
distance between the hob and the rear wall must
be at least 55 mm.
When there is an accessible space between the
built-in hob and the cavity below, a dividing wall
made of insulating material should be inserted
(wood or a similar material).
The wall should be at least 10 mm away from bot-
tom of the drawer. (fig. 2)
The Hob unit is fitted by attaching the Fixing Clamps supplied, using the holes at the base
of the unit.
Applying the sealant
Important - The diagram below shows how the sealant should be applied.
This appliance has been designed for non-professional, i.e. domestic, use.
Appropriate checks and tests have ensured that, even in the most extreme conditions,
the temperatures reached are within acceptable limits. The Hob is thermally insula-
ted (in line with Regulation EN) and may be installed: next to panels higher than
the worktop, for type «Y», or next to panels not higher than the worktop for type
«X». See technical characteristics table «Degree of protection».
Fig. 2
Partition panel
50 mm
min.
30 mm
10 mm
34
TECHNICAL CHARACTERISTICS
* Some models only ** Manufacturer setting
IE cat. II
2H3 +
GB cat. II
2H3 +
Cooking hobs 60x50
A
A
B
B
Burners
4 gas
4 gas
3 gas
3 gas
–
–
1 electric 1 electric
Reference type
PL01
PL02
PL01
PL02
Supply Voltage
(V/Hz)
230/50
230/50
230/50
230/50
Installed electric power
(W)
–
–
1400
1400
Medium burner
1
1
–
–
Large back burner
1
1
1
1
Small burner
1
1
1
1
Large front burner
1
1
1
1
Double ring burner
–
–
–
–
Maxi burner
–
–
–
–
Power of gas installed:
- G20/20 mbar (kW)**
8,2
8,2
6,7
6,7
- G30/28-30 mbar (g/h)
597
597
488
488
Electric ignition*
yes
yes
yes
yes
Gas safety device
–
yes
–
yes
Product size
mm.
595x510
595x510
595x510
595x510
Degree protection
–
–
Type Y
Type Y
Class
3
3
3
3
Fig. 1
Fig. 1b
MD
L
L
S
E
L
L
S