EN
5
INSTALLATION
Tumble dryers are supplied to operate at a
voltage of 230V, 50 Hz single phase. Check that
the supply circuit is rated to at least 10A
Electricity can be extremely dangerous.
This appliance must be earthed.
The socket outlet and the plug on the
appliance
must be of the same type.
Do not use multiple adapters and/or
extension
leads.
The plug should be accessible for
disconnection
after the appliance has been
installed.
The wires in the mains lead are coloured in
accordance with the following codes:
Blue
NEUTRAL
Brow
n
LIVE
Green and Yellow
EARTH
CE Appliance complies with European Directive
89/336/EEC, 73/23/EEC and subsequent
amendments.
Electrical Requirements
If the mains cord
on this
appliance is
d
amaged, it
must be
replaced by a
special cord
which is ONLY
obtainable from
the spares
service. It must
be installed by a
competent
person.
You may be
charged for a
service call if a
problem with
your machine is
caused by
incorrect installation.
Once the machine is in
place the feet should
be
adjusted to ensure
that the machine is
level.
Adjusting the Feet
Adequate ventilation must be provided in the
room where the tumble dryer is located to
prevent gases from appliances burning other
fuels, including open fires, being drawn into the
room during operation of the tumble dryer.
●
Exhaust
air
must
not
be
discharged
into
a
flue
which is used for exhausting fumes from
appliances burning gas or other fuels.
●
Check
regularly
that
the
air
flowing
through
the dryer is not restricted.
●
Check
the
fluff
filter
after
use
,
and
clean
,
if
necessary.
●
The
inlet
and
outlets
should
be
kept
free
from
obstructions. To ensure adequate ventilation
the space between the bottom of the machine
and the floor must not be obstructed. There
should be a gap of at least 12mm between the
machine and any obstructions.
●
Prevent
items
from
falling
or
collecting
behind
the dryer as these may obstruct the air inlet and
outlet.
●
NEVER install
the
dryer
up
against
curtains
.
VENTILATION
Do not plug the machine in and
switch it
on at the mains until the
installation is
completed.For your safety, this dryer must be
correctly installed.
If there is any doubt about
installation, call GIAS Service for
advice.
Air Outlets
Air Outlets in the Base
Air Inlent Vents
Do not install the product in a room where
there is a risk of frost occurring. At temperature
around freezing point the product may not be
able to operate properly: there is a risk of
damage if the water is allowed to freeze in the
hydraulic circuit (valves, hoses, pumps).
For a better product performance the ambient
room temperature must be b2°C and
+35°C.
Summary of Contents for GOC 781B
Page 57: ...40006342 ...