15
15
TABLE FOR THE CHOICE OF THE INJECTORS
LUBRICATION OF THE GAS TAPS
The operations must be executed by a qualified technician.
IMPORTANT
All intervention regarding installation and maintenance of the appliance must be
fulfilled with original factory parts.
The manufacturer declines any liability resulting from the non-compliance of this
obligation.
BURNERS
Nominal Power
Reduced Power
LPG (PROPANE/
BUTANE)
5 kPa
[g/h]
[kW]
[g/h]
[kW]
Ø injector
[1/100 mm]
Auxiliary (AUX)
73
1,00
25
0,34
46
Rapid (R)
219
3,00
73
1,00
79
AIR VENT NECESSARY FOR GAS COMBUSTION = (2 m
3
/h x kW)
BURNERS
Air necessary for combustion [m
3
/h]
Auxiliary (AUX)
2,00
Rapid (R)
6,00
Summary of Contents for CHW23PX SASO