THE LAST ALARM

Press the * key to finish.

You should test your system at regular intervals, to aid this a walk test

mode is provided. You are allowed to test all ALARM devices. DO NOT TEST
ANY PERSONAL ATTACK BUTTONS.

IMPORTANT.

If you have any problem with your system or any difficulty understanding it’s
operation please contact your Alarm Installer immediately. They will be
pleased to help.

4.6  LED DESCRIPTIONS

Here is a description of the four status LEDS on the keypad (Day Led Version).

LED NAME

COLOUR

OFF

ON

FLASHING

MAINS

GREEN

MAINS FAIL

MAINS ON

ENGINEERING

MODE

DAY

YELLOW

PANEL SET

PANEL UNSET

N / A

FAULT

YELLOW

BATTERY OK

BATTERY FAULT

THERE IS STILL A

BATTERY FAULT OR

CALL ENGINEER

YELLOW

LINE OK

LINE FAULT OR

FAILURE TO

COMMUNICATE

THERE IS STILL A

LINE FAULT OR

FAILURE TO

COMMUNICATE

Here is a description of the four status LEDS on the keypad (Normal Version).

LED NAME

COLOUR

OFF

ON

FLASHING

MAINS

GREEN

MAINS FAIL

MAINS ON

ENGINEERING

MODE

ENG

YELLOW

OK

CALL ENGINEER

N / A

FAULT

YELLOW

POWER

OK

POWER

FAULT

THERE IS STILL A

POWER FAULT

YELLOW

LINE OK

LINE FAULT OR

FAILURE TO

COMMUNICATE

THERE IS STILL A

LINE FAULT OR

FAILURE TO

COMMUNICATE

4.7

ALLOWING ENGINEER ACCESS

As a user, you can ( if previously selected ) Can allow, disallow the engineer
access to your panel. ( usually in high security areas ). To allow access to

Summary of Contents for Securit 703

Page 1: ...SECURIT 703 USER MANUAL C K Systems Ltd THE SECURIT 703 USER INSTRUCTIONS VERSION 1 4 September 1996 C031 111 03...

Page 2: ...for full set as above Then press the key followed by the 0 key The buzzer will change tone and the LED s for any zones programmed to be isolated in night set will flash The programmed Night set exit t...

Page 3: ...two tone alternating sound to indicate that there is a RESET REQUIRED Press the key to reset the system The green LED at the top left hand side of the keypad display is the Mains healthy light If thi...

Page 4: ...our four digit user code the buzzer will emit a steady sound and the exit time start Press the key followed by the 9 key The exit buzzer will stop and all LEDs will light After the 10 Second LED test...

Page 5: ...one to indicate the correct operation of that device The LED relating to that zone will light When the device test is over the sounder will stop and the zone LED will go out The buzzer will emit a low...

Page 6: ...ENGINEERING MODE DAY YELLOW PANEL SET PANEL UNSET N A FAULT YELLOW BATTERY OK BATTERY FAULT THERE IS STILL A BATTERY FAULT OR CALL ENGINEER YELLOW LINE OK LINE FAULT OR FAILURE TO COMMUNICATE THERE IS...

Page 7: ...then unset again The following is given so a record of your zone configurations can be made simply fill in where each zone is located in your premises Also you can fill in any relevant contact numbers...

Page 8: ...7 C K Systems Ltd Unit 24 Walkers Road North Moons Moat Industrial Estate Redditch Worcs B98 9HE Tel 44 0 1527 68111 Fax 44 0 1527 68222 email info cksys co uk http users powernet co uk cksys...

Reviews: