PRODUCT SPECIFICATIONS
Alarm relay:
Energized Form C (NC)
22 ohm series protection resistor
125 mA, 25 VDC
Range:
50' (15m) diameter
[25' (7.6m) radius]
Tamper switch:
Form A (NC)
25 mA, 30 VDC
Dimensions:
5" high x 5" wide x 2.3" deep
(12.7 cm x 12.7 cm x 5.8 cm)
Sensitivity:
2-4 normal steps
within field of view
PIR fields of view:
8'-11' (2.4m-3.3m)
mirror
Three 360
o
fields
36 long range zones
24 intermediate
16 short range
1 look-down
12'-16' (3.65m-4.8m)
mirror
Two 360
o
fields
40 long range zones
20 intermediate
1 look-down
Trouble output:
Open collector
voltage between
collector and
emitter (Vce) is
.3V max at 50 mA
(For future use)
PIR white light
immunity:
900 LUX
Power requirements:
10 - 12.9 VDC ,
typically 40 mA
50 mA maximum,
AC Ripple: 3 V peak-
to-peak at nominal
12 VDC
Operating
temperature:
32
o
to 120
o
F
(0
o
to 49
o
C)
Weight:
14 oz (397 g)
Relative
humidity
5% to 95%
(non-condensing)
Approvals/listings:
CE (EMC Directive)
FCC certified
UL listed
*ULC listed
IC certified
Standard accessories
included:
DT-6360STC recess kit;
PIR masking material
Command input:
Self-test initiate
Active low 0 to 1.5V
Inactive high 6 to V+
Input impedance
110K (minimum).
(For future use)
RF immunity:
30 V/m,
10 MHz-1000MHz
Frequencies:
Center band -
10.525 GHz (USA),
may vary in other
countries
For UL certificated installation, the DT-6360STC must be con-
nected to a UL listed power supply or UL listed control unit
capable of providing a minimum of four hours of standby power.
Important Notices
*The ULC label or listed marking on a product is the only evidence
provided by Underwriters Laboratories of Canada to identify products
that have been produced under the Listing and Follow-up Service.
4' (1.2m)
Above Floor
G
F
E
D
C
B
A
Mounting Height
4' (1.2m)
Floor
4' (1.2m)
Above Floor
E
D
C
B
A
4' (1.2m)
Mounting Height
CENTER
MOUNTING
HEIGHT
12' (3.65m)
14' (4.2m)
16' (4.8m)
OUTER TIER
INNER TIER
E
2.3'
(0.7m)
3.4'
(1.04m)
2.9'
(0.9m)
A
B
C
D
19.8'
(6m)
24.8'
(8m)
29.7'
(9m)
16.0'
(4.8m)
24.0'
(7.3m)
12.1'
(3.68m)
15.2'
(4.6m)
18.2'
(5.5m)
8.3'
(2.5m)
10.3'
(3.1m)
12.4'
(3.78m)
20.0'
(6m)
CENTER
MOUNTING
HEIGHT
8' (2.4m)
9' (2.7m)
11' (3.3m)
OUTER TIER
MIDDLE TIER
INNER TIER
A
B
C
D
E
F
25.3'
(8m)
31.6'
(9.6m)
44.3'
(13.5m)
18.8'
(5.7m)
23.5'
(7m)
33.0'
(10.1m)
11.8'
(3.6m)
14.8'
(4.5m)
20.7'
(6.3m)
9.0'
(2.7m)
15.8'
(4.8m)
5.6'
(1.7m)
7.0'
(2.1m)
9.8'
(3m)
4.3'
(1.3m)
5.4'
(1.7m)
7.5'
(2.3m)
G
1.7'
(0.5m)
2.1'
(0.6m)
2.9'
(0.9m)
11.3'
(3.4m)
The DT-6360STC should be tested at least once each year to