background image

18

TO DISARM THE SYSTEM:

Enter only through a TIME DELAY door.

If the ENTRY PRE-ALARM option is installed, the keypad will sound constantly until 10

seconds before the delay time expires (or the panel is disarmed), then beep rapidly for

the last 10 seconds.

.

OPTION

INSTALLED

Enter your PIN within

seconds and push the # key.

PIN

REQUIRED

Make sure the red ARM light on the keypad goes off.

If the ARM light does not go off, wait for the keypad to beep five times, then enter your

PIN again.

.

The keypad will beep twice to confirm that the system has been disarmed.

.

All bypasses are removed (except for 24-hour zones).

.

Summary of Contents for 236E

Page 1: ...Part Number 5 051 503 00 Rev A 1 2 5 4 7 8 3 6 9 0 PANIC P A G E...

Page 2: ...bel inside your keypad s door If you have any questions or need help with your alarm system call ______________________________________ ______________________________________ Alarm Company Name If you...

Page 3: ...er an alarm 19 Options 20 26 Changing a PIN 22 23 Deleting a PIN 23 Resetting smoke detectors 24 Door chime Keypad tones 25 26 Testing your system 27 28 Telephone trouble 29 Smoke detector placement 3...

Page 4: ...larm system works When a detection device is triggered the status of its zone goes from normal to FAULTED If armed the control panel responds by reporting an alarm condition on site flashing keypad li...

Page 5: ...only be installed if appropriate for your installation In addition some system features will require you to enter your personal identification number PIN As you read through this manual watch for box...

Page 6: ...ng battery System is armed protection is on System is not armed protection is off System is armed with delay zones converted to instant zones POWER ARM Normal state zone is not faulted ZONES Zone is f...

Page 7: ...g reset Normal state SERVICE POWER ARM and SERVICE FLASHING SLOW FLASHING FAST Failed to communicate The POWER ARM and SERVICE lights simultane ously flash slowly when in the programming mode Zone is...

Page 8: ...is in alarm circuit malfunction trouble on supervised loops only 5 beeps error tones invalid function unauthorized command attempted error changing PIN number wrong PIN number entered zone programmed...

Page 9: ...l pattern is in alarm This is the audible signal which UL has designated for fire protection zones trouble chirp 2 second chirp once every minute low battery conditon has been detected this will be ac...

Page 10: ...curity measure Pressing any key on the keypad will turn the ZONE lights back on OPTION INSTALLED Your PIN number is four digits long Don t pause for more than 5 seconds while entering the digits or th...

Page 11: ...ur installer can install However it s important for you to remember that no matter how your system is programmed you will always disarm it in the same way enter your PIN then push the key OPTION INSTA...

Page 12: ...while the system is armed Refer to the next three sections HOME ARMING INSTANT HOME ARMING and BYPASSING ZONES CAUTION When the system is instant armed you will not be able to enter through any perime...

Page 13: ...all the ZONE lights are off The red ARM light will be on while the system is armed PIN REQUIRED 4 Home Arming allows you to move about freely inside the premises while the system is armed You can ent...

Page 14: ...is armed Enter your PIN if required push the key enter the digit 7 the digit 4 then push the key PIN REQUIRED The red ARM light will flash while the perimeter zones are instant armed OPTION INSTALLED...

Page 15: ...a zone can be bypassed see the ZONE DESCRIPTION LIST on page 38 Enter your PIN if required PIN REQUIRED Push the key enter the digit 2 enter the zone to be bypassed then push the key 2 ZONE The ZONE l...

Page 16: ...ures for adding a bypass and removing a bypass are identical To remove a bypass enter your PIN push the key enter the digit 2 enter the zone from which the bypass is to be removed then push the key Wh...

Page 17: ...ed zone is cleared or manually bypassed FORCE ARMING Any zone except for 24 hour zones that is violated during the EXIT DELAY time will automatically be bypassed until the system is disarmed Warning b...

Page 18: ...disarmed then beep rapidly for the last 10 seconds OPTION INSTALLED Enter your PIN within seconds and push the key PIN REQUIRED Make sure the red ARM light on the keypad goes off If the ARM light doe...

Page 19: ...st to help you remember where the violations occurred PIN REQUIRED If this is a false alarm and no emergency response is needed call our central station IMMEDIATELY at to cancel the alarm Write down t...

Page 20: ...wn the 7 and 9 PANIC keys at the same time will trigger an alarm The keypad will beep twice to confirm the alarm condition OPTION INSTALLED 9 7 PANIC PAGE KEYS System 236E or later only When this opti...

Page 21: ...ring this code ____________ to disarm your system will send a special Ambush reporttothecentralmonitoringstationwithoutalertingtheassailant NOTE This feature is only active when the system is armed No...

Page 22: ...36E USER PIN Enter your master PIN push the key enter the digit 0 then push the key 0 MASTERPIN REQUIRED The POWER SERVICE and ARM lights will slowly flash Enter the User number 1 6 and push the key U...

Page 23: ...five times Try again If no key is pressed for 5 minutes the system will automatically exit the programming mode User 1 can use his Master PIN to delete the PINs of Users 2 6 Follow steps 1 through 4 f...

Page 24: ...doing the following Push the key enter the digit 6 the digit 2 and push the key 2 6 STANDBY BATTERY Should there be a loss of AC power the green POWER light on the keypad will go out and your alarm s...

Page 25: ...it 5 then push the key 5 KEYPAD TONE DISABLE You can disable the sounds the keypad makes for a variety of functions These functions include keypad feedback the keypad beeps everytime you press a key E...

Page 26: ...on and off Push the key enter the digit 5 the digit 2 and push the key 2 5 To turn the CONFIRMATION ERROR tones on and off Push the key enter the digit 5 the digit 4 and push the key 4 5 3 5 To turn t...

Page 27: ...e keypad lights go out the system will be ready for testing Walk through the areas protected by motion sensors open and close protected doors and windows Each time a zone is faulted its corresponding...

Page 28: ...is okay the keypad will beep twice If the battery is low or dead the POWER light will flash and the keypad will beep five times BELL SIREN TEST To test the bells sirens in your security system Enter y...

Page 29: ...is located If the trouble goes away when you unplug the control call us for service If you still have telephone trouble after unplugging the alarm system plug the system back in then call your telepho...

Page 30: ...icinityofbedrooms Innewconstruction asmokedetector shallbeinstalledineachseparatesleepingroom Heatorsmokedetectorsshouldbeinstalledinlivingrooms closets utility and storage rooms basements and attache...

Page 31: ...he other may be an easily opened window used if the primary escape path is blocked Sketch a floor plan showing doors windows stairs and rooftops that can be used for escape Indicate escape routes for...

Page 32: ...cted areas in your premises 24 HOUR ZONE A zone that is always active whether the system itself is armed or disarmed FIRE POLICE and EMERGENCY zones are usually 24 hour zones Alarm conditions on these...

Page 33: ...ck Smoke detectors used in conjunction with the alarm system may not sense fires that start where smoke cannot reach the detectors such as in chimneys walls or roofs or on the other side of closed doo...

Page 34: ...PINs masterPINrequired 1 Clears the alarm memory Bypasses individual zones PIN may be required 2 ZONE 4 Arms the system with interior zones bypassed PIN may be required 4 7 Converts Entry time delay z...

Page 35: ...ff 4 5 Turns the Error tones on off 6 0 Initiates the Local System Test PIN may be required 1 5 Turns the audible keypad feedback on off 2 6 Resets Smoke Detectors 3 6 Initiates the Bell Siren Test PI...

Page 36: ...e required 4 7 Converts Entry time delay zones to INSTANT if programmed to do so and arms perimeter zones while bypassing interior zones PIN may be required Refer to Instant Home Arming on page 14 7 P...

Page 37: ...weekly to make sure that all detection devices are working properly In addition if your system is being monitored you should periodically test its ability to transmit signals to our central station Th...

Page 38: ...38 ZONE LOCATION YES NO BYPASS 1 2 3 4 5 6...

Page 39: ...bel that contains the FCC registration number and the Ringer Equivalence Number REN for this equipment This information must be provided to your telephone company if requested The REN may be used to d...

Page 40: ...any cause to request the user to disconnect the equipment Repairs to this equipment should be made by an authorized agent of C K SYSTEMS Inc Contact your local alarm installation company for service U...

Reviews: