Automatic Hard Water Bypass During Regeneration 

The regeneration cycle can last 30 to 180 minutes, after which soft water service will be re-

stored. During regeneration, hard water is automatically bypassed for use in the household. 
Hot water should be used as little as possible during this time to prevent hard water from 
filling the water heater. This is why automatic regeneration is set for sometime during the 
night and manual regenerations should be performed when little or no water will be used in 

the household. 
 
Normal regeneration time is 2:00 AM. 

New Sounds

 

You may notice new sounds as your water softener operates. The regeneration cycle lasts 

up to 180 minutes. During this time, you may hear water running intermittently to the drain. 

When the system capacity is near exhausted, a regeneration is necessary to restore the sys-

tem to full capacity.  The table below explains the regeneration steps. 

Regeneration Process and Precision Brining

 

System Configuration 

Step  Name 

Description 

#1 

Brine Making 

A precise calculated amount of fresh water is added to the brine tank to make 
enough brine to regenerate only the exhausted portion of the ion exchange 
resin.  Note: 70% of the required fresh water is added in Step #5 in the previ-
ous regeneration.  The default brine making time is 30 minutes. 

#2 

Brine 

The brine solution is introduced slowly to the bottom of the tank flowing up 
through the ion exchange resin pushing the hardness out to drain and restor-
ing system capacity. 

#3 

Back Wash 

Fresh water is introduced to the bottom of the tank flowing upwards expand-
ing the ion exchange resin to rinse out any dirt or small particles to the drain 
and to un-compact the bed to restore full service flow rates. 

#4 

Rinse 

Fresh water is introduced from the top of the tank down flowing down through 
the ion exchange resin rinsing any excess brine solution out to the drain. 

#5 

Refill 

A fixed amount of soft water is added to the salt tank to prepare 70% of the 
fully saturated brine for the next regeneration.  Note: Step #1 will "top off" the 
amount of water needed based on the percentage of exhausted resin to be 
regenerated. 

Tank Size 

(Diameter)

Injector Set

Brine Line 

Flow Control 

(BLFC)

Drain Line 

Flow Control 

(DLFC)

9"

#2 (2.0 GPM)

10"

#3 (2.4 GPM)

685HE UPFLOW System Configuration

#0000 Black

0.20 GPM

Summary of Contents for WS685HET

Page 1: ...IDS THE WARRANTY BEFORE YOU BEGIN INSTALLATION READ THIS ENTIRE MANUAL THEN OBTAIN ALL THE MATERIALS AND TOOLS 1 Avoid pinched o rings during installation by applying provided with install kit NSF cer...

Page 2: ...g water that is microbio logically unsafe or of unknown quality without adequate disinfection before or after the system For your safety the information in this manual must be followed to minimize the...

Page 3: ...f daytime pressure is over 80 psi night time pressure may exceed the maximum Use a pressure reducing valve to reduce the pressure Softener resins may degrade in the pres ence of chlorine or chloramine...

Page 4: ...product improvements which may deviate from the specifications and descriptions stated herein without obligation to change previously manufactured products or to note the change The above capacity an...

Page 5: ...ched 6 foot power cable Extension cables are available Be sure the electric outlet and transformer are in an in side location to protect from wet weather If installing in an outside location you must...

Page 6: ...ailure to do this could cause damage to the valve 5 Connect the drain hose 10 ft included to the valve and secure it with a hose clamp also included Run the drain hose to the nearest laundry tub or fl...

Page 7: ...7 Installation Twin Tank...

Page 8: ...Allow the valve to refill for the full amount of time as dis played on the screen to insure a proper brine solution for the next regeneration 7 The valve will automatically advance to the SERVICE posi...

Page 9: ...need to maximize your capacity but still operate the system with good efficiency Choose IRON MN if you have problem water containing these minerals The high salt setting will be needed since these min...

Page 10: ...XT REGEN 06 DAYS LAST REGEN 9 24 12 TOTAL REGENS 10 TOTAL GALLONS 001590 GAL OVER RUN TOTAL 0500 GAL CURRENT 1 5 GPM PEAK 6 5 GPM DELAYED REGEN OFF REGEN TIME 2 00 AM REFILL TIME 3 00 MIN VALVE MODE S...

Page 11: ...sh water is added to the brine tank to make enough brine to regenerate only the exhausted portion of the ion exchange resin Note 70 of the required fresh water is added in Step 5 in the previ ous rege...

Page 12: ...only NUGGETor PELLET water softener salt Check the salt level monthly It is impor tant to maintain the salt level above the water level To add salt simply lift the salt lid and add the salt directly...

Page 13: ...ontrol valve body 3 Carefully remove the assembly and disassemble as shown in above figure 4 The injector orifice is removed from the valve body by carefully turning it out with a large screwdriver Re...

Page 14: ...t the BLFC holder apart and remove the flow washer 4 Reassemble using the reverse procedure TIP Markings on the BLFC washer should face the direction as shown here Replacing Drain Line Flow Control DL...

Page 15: ...a to form or grow However during shipping storage installing and operating bac teria could get into the softener For this reason sanitizing as follows is suggested when in stalling Sani System Liquid...

Page 16: ...55010023 SAFETY AIR CHECK ASSEMBLY H 1 30020006 BRINE TANK BTR 100 75 100 150 I 1 30020011 BRINE TANK BTR 145 200 I 1 30020032 BRINE TANK BTR 200 300 I 1 55010010 BRINE WELL CAP J K 1 REPLACEMENT PAR...

Page 17: ...Quantity 60010020 3 4 NPT ELBOW A 2 60010019 1 NPT STRAIGHT A 2 60010023 3 4 NPT STRAIGHT A 2 60010079 VALVE COUPLING INLET B 1 60010101 VALVE COUPLING OUTLET METER SIDE C 1 60010025 PLASTIC SECURE C...

Page 18: ...STON ASSEMBLY 60010035 INJECTOR SET 00 VIOLET 60010130 85HE SEAL SPACER KIT 60010034 INJECTOR SET 0 RED 60010131 85HE DLFC 1 1 5 GPM 60010033 INJECTOR SET 1 WHITE 60010132 85HE DLFC 2 2 0 GPM 60010032...

Page 19: ...65 A20 1 5056063 O Ring 78 74 5 33 A21 1 26010103 O Ring 25 3 55 A22 1 7060007 Valve Bottom Connector A23 1 13000426 Screw ST2 9X13 Large Washer A24 2 5031022 O Ring 32 3 A25 1 5031021 O Ring 18 3 A26...

Page 20: ...20 Power Head Exploded View...

Page 21: ...Screw ST2 9X13 Large Washer A24 2 5056139 Washer 3x13 B09 1 5030007 BNT85 Main Gear B10 1 5030005 BNT185 Housing B11 1 5031017 BNT85HE Brine Gear Downflow B12 1 5010023 Magnet 3 2 7 B13 1 5056141 Was...

Page 22: ...ne flow control DLFC button Check for proper flow rate 1 Plugged injector or screen Clean parts 2 Valve not regenerating Replace circuit board motor or control 3 Foreign material in brine valve Clean...

Page 23: ...n the gen eral conditions of this warranty General Conditions Damage to any part of this water conditioner as a result of misuse misapplication neglect alteration accident installation or operation co...