Automatic Hard Water Bypass During Regeneration 

The regeneration cycle can last 30 to 180 minutes, after which soft water service will be re-

stored. During regeneration, hard water is automatically bypassed for use in the household. 
Hot water should be used as little as possible during this time to prevent hard water from 
filling the water heater. This is why automatic regeneration is set for sometime during the 
night and manual regenerations should be performed when little or no water will be used in 

the household. 
 
Normal regeneration time is 2:00 AM. 

System Configuration 

Injector and Drain Line Flow Control 

Summary of Contents for WS665

Page 1: ...TY BEFORE YOU BEGIN INSTALLATION READ THIS ENTIRE MANUAL THEN OBTAIN ALL THE MATERIALS AND TOOLS 1 Avoid pinched o rings during installation by applying provided with install kit NSF certified lubrica...

Page 2: ...g water that is microbio logically unsafe or of unknown quality without adequate disinfection before or after the system For your safety the information in this manual must be followed to minimize the...

Page 3: ...ead free solder and flux for all sweat solder connections as required by state and federal codes Maximum allowable inlet water pressure is 125 psi If daytime pressure is over 80 psi night time pressur...

Page 4: ...ed to fill the cabinet or brine tank Water Temperature Min 39 F Max 100 F Operating Pressure Min 35 PSI Max 125 PSI Voltage 110 volts standard Units contain 8 Super Capacity Ion Exchange Resin At the...

Page 5: ...he war ranty Put the softener in a place water damage is least likely to occur if a leak develops The manufacturer will not repair or pay for water damage A 120 volt electric outlet to plug the in clu...

Page 6: ...ailure to do this could cause damage to the valve 5 Connect the drain hose 10 ft included to the valve and secure it with a hose clamp also included Run the drain hose to the nearest laundry tub or fl...

Page 7: ...7 Installation Twin Tank...

Page 8: ...RINSE position Check the drain line flow Allow the water to run for 3 4 minutes or until the water is clear 6 Press any button to advance to the REFILL position Check that the valve is filling wa ter...

Page 9: ...MANUAL REGEN again to ac cept the value 3 Press UP or DOWN to advance to the next option 4 At any time press SETTINGS to return to previous home screen menu If screen is locked press and hold SETTING...

Page 10: ...as your water softener operates The regeneration cycle lasts up to 180 minutes During this time you may hear water running intermittently to the drain About The System When the system capacity is nea...

Page 11: ...for use in the household Hot water should be used as little as possible during this time to prevent hard water from filling the water heater This is why automatic regeneration is set for sometime dur...

Page 12: ...only NUGGETor PELLET water softener salt Check the salt level monthly It is impor tant to maintain the salt level above the water level To add salt simply lift the salt lid and add the salt directly...

Page 13: ...by opening a cold soft water faucet 2 Using a screwdriver remove the two screws holding the injector cover to the control valve body 3 Carefully remove the assembly and disassemble as shown above The...

Page 14: ...t the BLFC holder apart and remove the flow washer 4 Reassemble using the reverse procedure TIP Markings on the BLFC washer should face the direction as shown here Replacing Drain Line Flow Control DL...

Page 15: ...a to form or grow However during shipping storage installing and operating bac teria could get into the softener For this reason sanitizing as follows is suggested when in stalling Sani System Liquid...

Page 16: ...Quantity 60010020 3 4 NPT ELBOW A 2 60010019 1 NPT STRAIGHT A 2 60010023 3 4 NPT STRAIGHT A 2 60010079 VALVE COUPLING INLET B 1 60010101 VALVE COUPLING OUTLET METER SIDE C 1 60010025 PLASTIC SECURE C...

Page 17: ...17 Control Valve Exploded View...

Page 18: ...2 A18 05056044 Adaptor Clip 2 A19 05056090 Screw ST4 2 13 Hexagon with Washer 2 A20 21709003 Secure Clip 2 A21 05056140 Valve Connector 1 A22 05056065 O ring 23 6 2 65 2 A23 21319006 Screw Adaptor 2...

Page 19: ...19 Power Head Exploded View...

Page 20: ...w ST2 9 10 5 B16 5056504 Bnt165 Pcb 1 B17 5056500 Bnt165 Front Cover 1 5056505 Bnt165 Operation Label 1 5056506 Bnt165 Regen Label 1 B18 5056509 Screw ST2 9 10 CSK 2 B19 5056082 Screw M3 5 2 B20 50565...

Page 21: ...ne flow control DLFC button Check for proper flow rate 1 Plugged injector or screen Clean parts 2 Valve not regenerating Replace circuit board motor or control 3 Foreign material in brine valve Clean...

Page 22: ...in the gen eral conditions of this warranty General Conditions Damage to any part of this water conditioner as a result of misuse misapplication neglect alteration accident installation or operation c...

Reviews: