12
System Start-Up
1. Plug the valve into an approved power source.
2. When power is supplied to the control, the screen will display “WAITING PLEASE” while it
finds the service position.
3. Start an Immediate Manual Regeneration. The valve will immediately start moving to the
BACKWASH position.
4. Open the inlet on the bypass valve slightly and very slowly allow water to enter the unit.
(If the water enters too quickly it will push the carbon up into the control valve and get
plugged).
5. Once the unit has filled sufficiently that water is at least equal to the height of the top of
the media shut down the water for 15 – 20 minutes for the carbon to soak. Unplug the
power cable. After the carbon has soaked for the recommended time continue by plug-
ging the power cable back in.
6. Turn the water back on slowly to backwash until water runs clear to drain.
7. Press any button to advance to the RINSE position. Check the drain line flow. Allow the
water to run for 3-4 minutes or until the water is clear.
8. The valve will automatically advance to the SERVICE position after the RINSE cycle is
complete. Open the outlet valve on the bypass, then open the nearest treated water fau-
cet and allow the water to run until clear, close the tap and replace the faucet screen.
9. Program time, date, and number of days between regenerations into controller using Pro-
gramming Instructions
Note : Carbon filters only:
Once the unit has filled sufficiently that water is at least equal to the height of the media
shut down the water for 15 – 20 minutes for the carbon to soak.
After the carbon has soaked for the recommended time continue with installation instruc-
tions.
Additional information for Non backwashing carbon filter.
After soaking, remove the aerator screen from the nearest faucet, run water at this faucet
until all fines (black) is gone from the water.
Start-up Instructions
Key Pad Configuration
SETTINGS
This
func on
is
to
enter
the
basic
set
up
informa on
required
at
the
me
of
installa on.
SELECT
Pressing
this
key
allows
the
user
to
change
the
value
of
each
se ng.
DOWN
/
UP
Increase
or
decrease
the
value
of
the
se ngs
while
in
the
program-
ming
mode.
Summary of Contents for HT765TO-75
Page 11: ...11 Filter Installation ...
Page 18: ...18 A A A B D F E A C Main Repair Parts Connectors ...
Page 19: ...19 Control Valve Exploded View ...
Page 20: ...20 Control Valve Parts List ...
Page 21: ...21 Power Head Exploded View ...
Page 22: ...22 Power Head Parts List ...
Page 23: ...23 Trouble Shooting ...