Canature WaterGroup Aqua Flo AQUV-8R1 Owner'S Manual Download Page 13

12

13

Category

AQUV-8R1

Maximum flow rate @ 30 mJ/cm

2

*

8 gpm / 30 lpm

Maximum flow rate @ 40 mJ/cm

2

*

5 gpm / 19 lpm

Lamp service life

9000 Hours

Lamp Power

35 watt

Power Consumption

35 watt

Annual lamp change timer

Yes

Lamp-ON Indicator

Yes

Audio/Visual alarms

Yes

Chamber material

304 Stainless Steel

Chamber dimensions (D x L)

3.5” x 16.0”

Controller dimensions (L x W x D)

8” x 3” x 2.25”

Inlet/Outlet port size

3/4"NPT

AC supply voltage

120V, 50/60Hz, 0.8A

Maximum operating pressure

100psi

Water temperature range

2 - 40°C (36-104°F)

Shipping Weight

26.5lb / 12kg

Item as 

Labelled

PART 

NUMBER

DESCRIPTION

QTY

1

40020068

Ballast, power cord & lamp connector assembly

1

2

80126734

Ballast mounting bolts

2

3

80126718

Ballast mounting nut

2

4

430335

SS UV Chamber for AQUV-8

1

5

Gland Nut

1

6

89587

Chamber Mounting SS Nut

1

7

36003037

Quartz Dome for AQUV-8

1

8

80127302

Dome O-Ring (Thicker)

1

9

80127301

Gland Nut O-Ring (Thinner) – inside nut

1

10

89112

UV Lamp for AQUV-8

1

11

80127402

Lamp Spring

1

12

36053

Pre-filter head

1

Sump for pre-filter

1

Pressure vent button

1

BH Mounting screw

4

BH mounting washer

4

Wrench to open pre-filter housing

1

13

36281

5 micron sediment cartridge

1

14

60010559

Sump O-rings

2

15

80036768

1”x3/4” reducer bushing

1

16

80036770

¾” street elbow

2

17

80030391

¾” Close Nipple

1

18

80127829

¾” x ¾” Flex Tube, 24”

1

19

89588

UV Bracket - Single Sump

1

Replacement Parts

System

AQUV-8R1

Item #

40030104

Lamp

89112

Quartz Dome

36003037

Controller

40020068

5 Micron Sediment Cartridge 10"

36281

(I) TECHNICAL SPECIFICATIONS

(J) PARTS LIST

4

10

19

8

7

11

18

13

14

2 3

12

12

12

12

6

16

17

15

1

5 9

 *Dosage based on a UVT value of 96%

Summary of Contents for Aqua Flo AQUV-8R1

Page 1: ...nstalled in accordance with local plumbing codes 3 Test the water periodically to verify that the system is performing satisfactorily 4 Discard small parts remaining after the installation 5 Failure t...

Page 2: ......

Page 3: ...rganisms present in the water supply Simple maintenance continuous disinfection and ultimately safe water AQUA FLO makes it that easy A INTRODUCTION 4 B SAFETY GUIDELINES 4 C WATER QUALITY REQUIREMENT...

Page 4: ...any harmful disinfection by products Fig 1 Lamp contains mercury Hg Dispose or recycle in accordance with applicable laws For information on safe handling procedures and safe disposal and recycling c...

Page 5: ...the power outlet by holding the plug Never pull the cord To comply with the National Electrical Code and to provide additional protection from the risk of electric shock this system should only be co...

Page 6: ...he system must be installed in accordance with all local state or provincial regulations The system requires a constant power supply of 110V AC It is strongly recommended to have a dedicated electrica...

Page 7: ...k If you have other water filters conditioner installed such as softener iron filter etc the UV system should always be installed as the last step of treatment before the water pipes divide into hot a...

Page 8: ...the new cartridge into the sump and screw the sump back onto the filter Hand tighten only 4 Carefully unpack UV lamp and quartz dome Two o rings come with the quartz dome The thinner o ring is instal...

Page 9: ...ugh the plastic making it easy to hook up lamp then white plastic part has a little screw to secure it to the gland nut 11 Remove the nut from the ground stud at the top of the unit Next place the gro...

Page 10: ...s minimal 7 You are ready to use the water now F BALLAST FOR AQUV UV SYSTEMS Aqua Flo AQUV advanced micro processor controlled electronic UV ballast is for use with Aqua Flo AQUV 8 AQUV12 AQUV 20 Syst...

Page 11: ...rd old cartridge and rinse sump 4 Remove O rings and replace if they have been in use for a year Otherwise wipe them with a soft cloth or paper towel and clean the groove on which the O rings are seat...

Page 12: ...l re set the lamp change timer to zero and the 3 second beep will confirm that the re set was successful Winterizing Your System To winterize the system unplug the unit first Drain the pre filter by r...

Page 13: ...nut 2 4 430335 SS UV Chamber for AQUV 8 1 5 Gland Nut 1 6 89587 Chamber Mounting SS Nut 1 7 36003037 Quartz Dome for AQUV 8 1 8 80127302 Dome O Ring Thicker 1 9 80127301 Gland Nut O Ring Thinner insi...

Page 14: ......

Page 15: ......

Page 16: ...ding any warranty of merchantability or fitness for a particular purpose and excludes all other express or implied warranties to the extent permitted by law For clarity where exclusion is not permitte...

Reviews: