Canature WaterGroup 89DF Owner'S Manual Download Page 27

26

27

Sani-System Liquid Sanitizer Concentrate

Item #50033 One (1) packet –  

conditioner sanitizer. 2.5 fl oz [7.4 ml]

SANITIZATION PROCEDURE

SYSTEM MAINTENANCE

Maintenance of your new water softener requires very little time or effort but is essential. Regular maintenance will ensure many years of 

efficient and trouble-free operation. Check with your local dealer about setting up a regular maintenance plan.Failure to follow  

maintenance instructions and schedule will result in the unit failing to operate properly and void your warranty.

SERVICE SCHEDULE

— 

The seals and spacers along with the piston assembly should be inspected/cleaned or replaced annually or as required  

  depending on the inlet water quality and water usage. See Inspection and Replacement of Piston Assembly and Seal and Spacer Kit.

— 

The injectors should be cleaned/inspected or replaced annually or as required depending on the water quality and use.  

  See Clean Injector Assembly. 

— 

Your inlet water quality and water consumption will determine how often the media should be replenished  or replaced.    

 

 

  Check with your water treatment expert for the media bed change frequency. 

— 

Maintenance materials – Please see  Common Spare Parts.

CARE OF YOUR SOFTENER

To retain the attractive appearance of your new water softener, occasionally clean it with a mild soap solution. Do NOT use abrasive cleaners, 

ammonia, or solvents. 

TO SANITIZE:

1.  Be sure to complete all installation steps, including programming before sanitizing.
2.  For effective and complete sanitization, Sani-System Liquid Sanitizer Concentrate is recommended. Pour one packet into the  

 

 

 

brine well located in the cabinet or brine tank. Alternatively use 3/4 fl oz [22 ml] of common household bleach.

3.  Start an immediate regeneration.
4.  The solution in the brine well is drawn into and through the water conditioner to sanitize itself. This sanitizing regeneration  

 

 

 

takes two (2) hours. Then, treated water is available for your use. 

Sanitizing is recommended by the Water Quality Association for disinfecting. Quarterly sanitizing is suggested for low-quality water supplies.

Care is taken at the factory to keep your water conditioner clean and sanitary. Materials used to make the conditioner will not infect or contaminate 

your water supply, and will not cause bacteria to form or grow. However, during shipping, storage, installing, and operating, bacteria could get into 

the conditioner. For this reason, sanitizing is suggested when completing installation.

Summary of Contents for 89DF

Page 1: ...eration 4 Avoid pinched O rings during installation by applying NSF certified lubricant to all seals provided with install kit 5 This system is not intended for treating water that is microbiologicall...

Page 2: ...R PARAMETERS 7 UNPACKING INSPECTION 8 BEFORE INSTALLATION 9 PREPARATIONS 10 PLANNING YOUR INSTALLATION 13 INSTALLATION STEPS 16 UNDERSTAND THE SCREEN KEYPAD CONFIGURATION 18 START UP INSTRUCTIONS 19 O...

Page 3: ...warranty The warranty provided gives you specific legal rights and otherwise limits your legal rights to the extent permitted by law By installing and or using this product you are accepting these li...

Page 4: ...al number and valve serial number in the Records Contacts section as they will be important if you need to troubleshoot NOTE For cabinet models the model number and the system serial number are locate...

Page 5: ...or 40 F 110 F Do NOT expose softener to freezing temperatures or vacuum Discharge lines exposed to freezing temperatures should be positioned with a downward slope Do NOT expose softener to direct su...

Page 6: ...r use is at its minimum Use of water during the regeneration time will result in hard untreated water being used FEATURES TERMINOLOGY Flow Rate It will only display if treated water is running otherwi...

Page 7: ...tact Information Is displayed when available At the stated service flow rates the pressure drop through these devices will not exceed 15 psig Peak flow rates are intended for intermittent use only 10...

Page 8: ...rts box until you are ready to use them What is included in the box For Models 075 100 150 200 250 300 you will expect the following 1 Control Valve 2 Pressure Tank 3 Parts Box 4 Brine Tank Assembly 5...

Page 9: ...them Softener resins will degrade in the presence of chlorine or chloramines above one 1 ppm If you have anything in excess of this amount you will experience reduced life of the resin Carbon filtrat...

Page 10: ...er part 99003 separately for your own funnel Slowly add the gravel Depending on the type of system add the resin or media next Support Bed Gravel Media MANDATORY Wear a Dust Mask Airborne particles co...

Page 11: ...5 Remove the tape from the top of the riser tube Carefully position the valve over the riser tube inserting riser into the internal O ring Turn the valve clockwise into the threads of the tank until s...

Page 12: ...or installation of brine tank at the installation site pull the other end of the brine tube from the hole on the brine tank The completed assembly is below 3 Place the brine grid with the brine well i...

Page 13: ...hould be located before the water heater on the supply line If closer than three 3 metres 10 feet install a check valve in accordance with local plumbing codes 7 Do NOT install a softener in a locatio...

Page 14: ...ptional Pipes Fixed Structure Drain Elbow Assembly Outlet BrineTank 3 8 BrineTube Inlet Upflow Valve Outlet Brine Elbow Assembly Bypass assembly Outlet Inlet Drain Elbow Assembly Floor drain Optional...

Page 15: ...Drain Elbow Assembly Outlet BrineTank 3 8 BrineTube Inlet 5 8 Overflow Line Optional Brine Elbow Assembly Bypass assembly Outlet Inlet Drain Elbow Assembly Floor drain Optional Pipes Fixed Structure...

Page 16: ...or elbow plumbing adaptors 3 Apply the supplied lubricant 92360 to the O rings of the fittings 4 Connect the supplied straight or elbow plumbing adaptors to the bypass with red clips 5 Connect the inl...

Page 17: ...ervice OPEN the bypass valve by rotating the knobs back to the SERVICE position NOTE Please make sure bypass knobs are completely open otherwise the untreated water may enter through the valve INSTALL...

Page 18: ...position as shown below The control valve is controlled with simple user friendly electronics displayed on an LCD screen Connect theTransformer Connect the transformer to the unit by plugging the 12...

Page 19: ...tank cabinet salt lid and fill with water until there is approximately 1 25 4 mm of water above the grid plate 2 If there is no grid plate fill the tank with 3 75 mm of water Do NOT add salt to the br...

Page 20: ...e Press button three 3 to Confirm 3 Setting complete 1 Press and hold button one 1 the display will read PRESS 5 Seconds to Unlock 2 After 5 seconds the display will beep confirming unlock 3 Press but...

Page 21: ...per gallon of the raw water supply It is used to calculate the system capacity If Ferrous Iron is present add 4 gpg for every 1 ppm of Ferrous Iron This unit is factory set for the correct size You a...

Page 22: ...s To Cancel Press To Confirm 1 Press buttons two 2 or four 4 to select Manual Regen Press button three 3 to Confirm 1 Press buttons two 2 or four 4 to select Dealer Information Press button three 3 to...

Page 23: ...ress buttons two 2 or four 4 to select Advanced Menu Press and hold button three 3 for five 5 seconds to enter 1 3 2 4 Advanced Menu BacklightSettings HistoryValues SaltReminderSet AlarmOption BrinePr...

Page 24: ...s button three 3 to enter 8 Select the time of day for the salt reminder alarm to sound Press buttons two 2 or four 4 to select a number Press button three 3 to advance to the next position 1 3 2 4 Sa...

Page 25: ...e display will read PRESS 5 Seconds to Unlock 2 After 5 seconds the display will beep confirming unlock MANDATORY Programming changes are necessary to compensate for the injector conversion CAUTION DO...

Page 26: ...the water heater OFF and shut the heater inlet water valve OFF 2 Drain hot water tank completely OPEN the InletWaterValve allowing the heater tank to be refilled with iron free water Continue flushin...

Page 27: ...requency Maintenance materials Please see Common Spare Parts CARE OF YOUR SOFTENER To retain the attractive appearance of your new water softener occasionally clean it with a mild soap solution Do NOT...

Page 28: ...ions happen or the unit fails to regenerate for any other rea son correct the problem first then regenerate the unit manually Regener ate two times in a row to restore the reserve capacity and bring t...

Page 29: ...er and drill 1 Measure 2 inches from the top of the tank beside the oblong molding 3 Install the holder 5 Take off the small hole cover on the BrineWell lid 4 Hang the Res Care bottle on the hanger 6...

Page 30: ...SERVICING YOUR CONTROL VALVE BEFORE SERVICING YOU WILL NEED TO 1 Shut the water supply to the softener OFF put the softener into the BYPASS position 2 Relieve water pressure in the softener by steppi...

Page 31: ...nd put back in 5 Replace seal and spacer set as shown Place spacer in then a seal and repeat until finishing with a seal 6 Lubricate the piston assembly with silicone lubricant Part 92360 and then rep...

Page 32: ...ight side of the control valve when facing your softener The assembly is easy to clean start by 1 Shut the water supply to your softener OFF 2 Reduce the pressure by opening a cold treated tap 3 Using...

Page 33: ...Check programming and reset as needed 3 UNIT USES TOO MUCH SALT A Improper salt setting B Excessive water in brine tank C Improper programming A Check salt usage and salt setting B See 7 C Check prog...

Page 34: ...nternal control leak C Control valve jammed in brine or backwash position D Timer motor stopped or jammed teeth E Timer not operating properly A Remove piston assembly and inspect bore Remove foreign...

Page 35: ...3 4 NPT Comes with O Ring 60090030 Elbow Drain line 1 NPT Comes with O Ring 60090028 Drain Line Hose Barb 60010227 Drain Line Red Clip 92387 Large Red Bypass Clip 60010069 Brine Line Red Clip 60010006...

Page 36: ...sed by any force of nature is not covered in this warranty At our sole discretion we will repair or replace defective parts if our warranty department determines it to be defective under the terms of...