Canature WaterGroup 185DF Series Owner'S Manual Download Page 4

4  

Specifications and Performance Data Sheet 

Before Starting Installation 

Tools, Pipe, and Fittings, Other Materials 

 

Pliers 

 

Screwdriver 

 

Teflon tape 

 

Razor knife 

 

Two adjustable wrenches 

 

Additional tools may be required if modifi-
cation to home plumbing is required. 

 

Plastic inlet and outlet fittings are included 

with  the  softener.    To  maintain  full  valve 

flow, 3/4” or 1” pipes to and from the sof-

tener  fittings  are  recommended.  You 

should  maintain  the  same,  or  larger,  pipe 
size  as  the  water  supply  pipe,  up  to  the 
softener inlet and outlet. 

 

Use copper, brass, or PEX pipe and fittings. 

 

Some  codes  may  also  allow  PVC  plastic 

pipe. 

 

ALWAYS  install  the  included  bypass  valve, 
or 3 shut-off valves. Bypass valves let you 
turn off water to the softener for repairs if 

needed,  but  still  have  water  in  the  house 
pipes. 

 

5/8” OD drain line is needed for the valve 

drain.    A  10’  length  of  hose  is  included. 

with some models. 

 

A  length  of  5/8”  OD  drain  line  tubing  is 

needed for the brine tank over flow fitting 
(optional). 

 

Nugget  or  pellet  water  softener  salt  is 
needed to fill the cabinet or brine tank. 

 

Continuous operation at flow rates greater than the service flow rate may affect capacity and efficiency performance. 

 

The manufacturer reserves the right to make product improvements which may  deviate  from the  specifications  and 
descriptions stated herein, without obligation to change previously manufactured products or to note the change. 

 

The above capacity and flow rate specifications have not been validated by WQA. 

Specifications 

WG185DF-24C 

WG185DF-32C 

WG185DF-24 

WG185DF-32 

WG185DF-40 

WG185DF-64 

WG185DF-96 

2110 

2111 

2112 

2113 

2114 

2115 

2116 

Optional Settings - High Efficiency 

  

          Salt Used - Per Regeneration 

2.3 lbs 

3.0 lbs 

2.3 lbs 

3.0 lbs 

3.75 lbs 

6.0 lbs 

9.0 lbs 

          Water Used - Regeneration 

22.7 gal 

28.3 gal 

22.6 gal 

31.6 gal 

39.5 gal 

60.9 gal 

102.2 gal 

          Hardness Removal - Grains 

11,250 

15,000 

11,250 

15,000 

18,750 

30,000 

45,000 

Factory Settings - Standard Capacity 

  

          Salt Used - Per Regeneration 

4.5 lbs 

6.0 lbs 

4.5 lbs 

6.0 lbs 

7.5 lbs 

12.0 lbs 

18.0 lbs 

          Water Used - Regeneration 

40.5 gal 

48.6 gal 

34.0 gal 

43.4 gal 

54.3 gal 

87.1 gal 

139.2 gal 

          Hardness Removal - Grains 

18,750 

25,000 

18,750 

25,000 

31,250 

50,000 

75,000 

Optional - High Capacity 

  

          Salt Used - Per Regeneration 

7.5 lbs 

10.0 lbs 

7.5 lbs 

10.0 lbs 

12.5 lbs 

20.0 lbs 

30.0 lbs 

          Water Used - Regeneration 

56.1 gal 

69.5 gal 

49.6 gal 

64.3 gal 

80.37 gal 

124.6 gal 

196.2 gal 

          Hardness Removal - Grains 

22,500 

30,000 

22,500 

30,000 

40,000 

60,000 

90,000 

Resin Quantity - Cubic Feet 

0.75 ft

1.0 ft

0.75 ft

1.0 ft

1.25 ft

2.0 ft

3.0 ft

Tank Size 

9x35 

10x35 

9x35 

10x35 

10x47 

12x52 

14x65 

Tank Jacket / Media Loaded 

Yes 

Yes 

Yes 

Yes 

Yes 

No 

No 

Brine Tank / Cabinet Size (Inches) 

16.5 x 19.3 x 43.3 16.5 x 19.3 x 43.3 

18.1 x 34.5 

18.1 x 34.5 

18.1 x 34.5 

20.3 x 37.4 

23.0 x 40.5 

Salt Storage Capacity  

175 lbs 

175 lbs 

240 lbs 

240 lbs 

240 lbs 

350 lbs 

420 lbs 

Flow Rate @ 15 psi Pressure Drop 

11.6 gpm 

12.0 gpm 

10.4 gpm 

11.0 gpm 

12 gpm 

12.2 gpm 

12.6 gpm 

Flow Rate @ 25 psi Pressure Drop 

15.6 gpm 

16.0 gpm 

14.3 gpm 

15.0 gpm 

15.5 gpm 

16.2 gpm 

16.6 gpm 

Back Wash Flow Rate 

2.0 gpm 

2.4 gpm 

2.0 gpm 

2.4 gpm 

2.4 gpm 

3.5 gpm 

5.0 gpm 

Shipping Weight 

93 lbs 

110 lbs 

105 lbs 

122 lbs 

154 lbs 

172 lbs 

244 lbs 

Regeneration Type 

Co Current / Down Flow 

Plumbing Connections 

Includes 3/4" 90°Elbows & 1" Straight NPT 

Resin Type 

Aquafine 8% High Capacity Ion Exchange Resin 

Electrical Requirements 

Input 120V 60 Hz - Output 12V 650mA 

Water Temperature 

Min 39  - Max. 100 degrees Fahrenheit 

Water Pressure 

Min. 20 - Max. 125 psi 

Summary of Contents for 185DF Series

Page 1: ...E WARRANTY BEFORE YOU BEGIN INSTALLATION READ THIS ENTIRE MANUAL THEN OBTAIN ALL THE MATERIALS AND TOOLS 1 Avoid pinched O rings during installation by applying provided with install kit NSF certified...

Page 2: ...g water that is microbiologi cally unsafe or of unknown quality without adequate disinfection before or after the system For your safety the information in this manual must be followed to minimize the...

Page 3: ...re may exceed the maximum Use a pressure reducing valve to reduce the pressure Softener resins may degrade in the pres ence of chlorine or chloramines above 2 ppm If you have chlorine or chloramines i...

Page 4: ...fficiency Salt Used Per Regeneration 2 3 lbs 3 0 lbs 2 3 lbs 3 0 lbs 3 75 lbs 6 0 lbs 9 0 lbs Water Used Regeneration 22 7 gal 28 3 gal 22 6 gal 31 6 gal 39 5 gal 60 9 gal 102 2 gal Hardness Removal G...

Page 5: ...hed 6 foot power cable Extension cables are available Be sure the electric outlet and transformer are in an in side location to protect from wet weather If installing in an outside location you must t...

Page 6: ...his could cause damage to the valve 5 Connect the drain hose 10 ft included to the valve and secure it with a hose clamp also included Run the drain hose to the nearest laundry tub or floor drain This...

Page 7: ...7 Installation Twin Tank...

Page 8: ...Allow the valve to refill for the full amount of time as dis played on the screen to insure a proper brine solution for the next regeneration 7 The valve will automatically advance to the SERVICE posi...

Page 9: ...need to maximize your capacity but still operate the system with good efficiency Choose IRON MN if you have problem water containing these minerals The high salt setting will be needed since these mi...

Page 10: ...EXT REGEN 06 DAYS LAST REGEN 9 24 12 TOTAL REGENS 10 TOTAL GALLONS 001590 GAL OVER RUN TOTAL 0500 GAL CURRENT 1 5 GPM PEAK 6 5 GPM DELAYED REGEN OFF REGEN TIME 2 00 AM REFILL TIME 3 00 MIN VALVE MODE...

Page 11: ...table below explains the regeneration steps Regeneration Process and Precision Brining System Configuration Step Name Description 1 Brine The brine solution is introduced slowly to the tank flowing do...

Page 12: ...only NUGGETor PELLET water softener salt Check the salt level monthly It is im portant to maintain the salt level above the water level To add salt simply lift the salt lid and add the salt directly...

Page 13: ...ontrol valve body 3 Carefully remove the assembly and disassemble as shown in above figure 4 The injector orifice is removed from the valve body by carefully turning it out with a large screwdriver Re...

Page 14: ...t the BLFC holder apart and remove the flow washer 4 Reassemble using the reverse procedure TIP Markings on the BLFC washer should face the direction as shown here Replacing Drain Line Flow Control DL...

Page 15: ...a to form or grow However during shipping storage installing and operating bac teria could get into the softener For this reason sanitizing as follows is suggested when in stalling Sani System Liquid...

Page 16: ...Quantity 60010020 3 4 NPT ELBOW A 2 60010019 1 NPT STRAIGHT A 2 60010023 3 4 NPT STRAIGHT A 2 60010079 VALVE COUPLING INLET B 1 60010101 VALVE COUPLING OUTLET METER SIDE C 1 60010025 PLASTIC SECURE C...

Page 17: ...STON ASSEMBLY 60010035 INJECTOR SET 00 VIOLET 60010130 85HE SEAL SPACER KIT 60010034 INJECTOR SET 0 RED 60010131 85HE DLFC 1 1 5 GPM 60010033 INJECTOR SET 1 WHITE 60010132 85HE DLFC 2 2 0 GPM 60010032...

Page 18: ...1 5030013 O Ring 30 2 65 A20 1 5056063 O Ring 78 74 5 33 A21 1 26010103 O Ring 25 3 55 A22 1 7060007 Valve Bottom Connector A23 1 13000426 Screw ST2 9X13 Large Washer A24 2 5031022 O Ring 32 3 A25 1...

Page 19: ...19 Power Head Exploded View...

Page 20: ...Drive Gear B08 1 13000426 Screw ST2 9X13 Large Washer A24 2 5056139 Washer 3x13 B09 1 5030007 BNT85 Main Gear B10 1 5030005 BNT185 Housing B11 1 5031017 BNT85HE Brine Gear Downflow B12 1 5010023 Magn...

Page 21: ...ne flow control DLFC button Check for proper flow rate 1 Plugged injector or screen Clean parts 2 Valve not regenerating Replace circuit board motor or control 3 Foreign material in brine valve Clean...

Page 22: ...d shall be from the date thereof Life Time Warranty on Mineral Tanks and Brine Tanks WaterGroup will provide a replacement mineral tank or brine tank to any original equipment purchaser in possession...

Reviews: