GSQ-SERES
USER MANUAL
2015.11.28
PAGE 7 OF 10
2157 Parkedale Avenue, Brockville,
Ontario, Canada, K6V 6v6
1 (613) 342-5424
PRE-START INSPECTION
1.
Lock out all power sources.
2.
Inspect all fasteners and set screws and tighten as required.
3.
Confirm power source voltage and motor voltage are the same and that the motor is
wired correctly.
4.
Rotate the wheel to ensure that neither the fan blade nor the belts come into contact
with the housing.
5.
Inspect the fan and the ductwork to ensure they are free of debris.
6.
Check to ensure that all guards and accessories are securely mounted.
START-UP
Turn the fan on and inspect for the following:
1.
Direction of rotation.
2.
Improper motor amperage.
3.
Excessive vibration.
4.
Unusual noise.
If a problem is discovered shut off the fan and refer to the section on troubleshooting to
discover the cause of the problem. The fan should be inspected after 30 minutes, 8 hours and
24 hours of operation to ensure all fasteners are tight and belts are properly tensioned and
aligned.