10
Canarm Octa-Lite 8LEC Series
5
MOUNTING METHOD 1: UNI-STRUT
5.1 Select Proper Unistrut:
NOTE:
Unistrut and Unistrut hardware is not included with the fan. This equipment must be field
supplied.
(2) 1-5/8” Unistrut Channels (not provided).
If the spanning distance is greater than 8 feet, please consult a structural engineer.
Span two (2) pieces of 1-5/8” Unistrut open side facing down and space apart so there is 12-7/8” from
outside edge to outside edge.
Once the Unistrut is in place, apply liquid thread lock to the recommended bolts and use the
remaining recommended hardware to attach the mount to the Unistrut.
Follow the table below when selecting Unistrut for fan installation. PLEASE NOTE: These are
recommendations. Canarm is not liable for accidents resulting from improperly sized mounting
methods. Please consult a structural engineer.
Unistrut Span
(between
mounting
point)
Minimum
Unistrut Size
(W x H x T)
Qty. of
Unistrut
Needed
< 8’ (2.4m)
1-5/8”
2
Support Directly From Building Structure.
All mounting instructions assume that the building structure from which the fan will be
hung is of sound construction, undamaged, and capable of supporting loads of up to
650 lbs (295 kg). It is the sole responsibility of the customer to verify that the building’s
structure is adequate for fan installation. Canarm recommends consulting with a
structural engineer prior to fan installation.
Aider directement à la structure du bâtiment.
Toutes les instructions de montage supposent que la structure du bâtiment à partir de laquelle le
ventilateur sera pendu est de construction solide, en bon état, et capable de supporter des charges
de jusqu’à 650 lb (295 kg). Il est de la seule responsabilité du client de vérifier que la structure du
bâtiment est suffisante pour l’installation du ventilateur. Canarm recommande de consulter un
ingénieur en structure avant d’attiser installation.
WARNING/ AVERTISSEMENT
!