CanadianSolar CSI-25K-T220GL03-E Installation And Operation Manual Download Page 25

.49.

.48.

7.5.7 Special Settings

This function is applicable by maintenance personnel only, wrong operation 

will prevent the inverter from reaching maximum power.

7. Normal operation

7. Normal operation

This function controls the 24H hours consumption function enable or disable.

Enable
Disable

Figure 7.20 Set 24H ON/OFF

7.5.2.2 24H Switch

7.5.3 Clear Energy

Clear Energy can reset the history yield of inverter

These two functions are applicable by maintenance personnel only, wrong 

operation will prevent the inverter from working properly.

7.5.4 Reset Password

This function is used to set the new password for menu “Advanced info.” and “Advanced 

information” .

Figure 7.21 Set new password

YES=<ENT> NO=<ESC>

Password: 0000

Enter the right password before set new password. Press the DOWN key to move the cursor, 

Press the UP key to revise the value. Press the ENTER key to execute the setting. 

Press the ESC key to return to the previous menu. 

7.5.6 Calibrate Energy

Maintenance or replacement could clear or cause a different value of total energy. Use this 

function could allow user to revise the value of total energy to the same value as before. If 

the monitoring website is used the data will be synchronous with this setting automatically.

Figure 7.22 Calibrate energy

YES=<ENT> NO=<ESC>

Energy:0000000kWh

Press the DOWN key to move the cursor. Press the UP key to revise the value. Press the 

ENTER key to execute the setting. Press the ESC key to return to the previous menu. 

7.5.5 Power Control

Active and reactive power can be set through power setting button.

There are 4 item for this sub menu:

1. Set output power     

2. Set Reactive Power    

3. Out_P With Restore     

4. Rea_P With Restore        

This function is applicable by maintenance personnel only, wrong operation 

will prevent the inverter from reaching maximum power.

NOTE: 

When this is enabled, the inverter LCD will still be alive at night with 
the power LED light on. If the grid is in malfunction at night, the system can’t 
recover even after the grid is back to normal but the consumption data will 
still be recorded in the meter. Until the sunrise, the system will start to work 
again while the meter data can be uploaded to the Canadian Solar monitoring 
system to calibrate the load consumption data.

Summary of Contents for CSI-25K-T220GL03-E

Page 1: ...ail sales au csisolar com Customer Support Email service au csisolar com South East Asia 101 Thompson Road 15 03 United Square Singapore 307591 P 65 6572 905 F 65 6559 4690 Sales Inquires Email sales...

Page 2: ...Shutdown 6 1 Start up procedure 6 2 Shutdown procedure 39 39 39 7 1 Main Menu 40 42 7 2 1 Lock screen 40 7 2 Information 4 1 Inverter monitoring connection 28 7 Normal operation 40 4 2 DRM Connection...

Page 3: ...n Solar distributor Cross screws M4 14 x4 Cross Recessed Hexagon Bolt M6 12 x2 User manual x1 Manual AC terminal cover x1 DC connectors 25 30 K x8 50K x10 60K x12 4pin COM Port 16pin COM Port 16pin CO...

Page 4: ...tallations must be done in accordance with local and national electrical safety standards 1 3 Storage 2 Safety Instructions WARNING To reduce the risk of fire branch circuit over current protective de...

Page 5: ...ff before the DC Switch is turned off 2 3 Notice for use 2 Safety Instructions 3 1 Environmental considerations 3 1 1 Select a location for the inverter When selecting a location for the inverter cons...

Page 6: ...electricity supply the sound level from the inverter can be quite high 3 2 Product handling Figure 3 3 Handles used to move the inverter shown circled in red 3 1 2 4 Air circulation Do not install in...

Page 7: ...ally The steps to mount the inverter are listed below 1 Refer to Figure 3 6 drill holes for expansion bolt M10 90 based on the hole diameter of bracket using a precision drill keeping the drill perpen...

Page 8: ...from vertical The steps to mounted to the rack are listed below 3 Install mounting plate 1 Remove the bracket and fasteners from the packaging Mark the position for hole drilling according to the hol...

Page 9: ...he Grid Supply Main Switch AC OFF 2 Switch the DC Isolator OFF 3 Connect the inverter to the grid 4 Assemble PV connector and connect to the Inverter Inverter design uses PV style quick connect termin...

Page 10: ...nding 2 Prepare OT terminals M10 To effectively protect the inverter two grounding methods must be performed Connect the AC grounding cable Please refer to section 3 4 3 Connect the external grounding...

Page 11: ...This can cause serious damage to the inverter WARNING MAKE SURE the polarity of the PV array output conductors matches the DC and DC terminal labels before connecting these conductors to the terminal...

Page 12: ...d between the inverter and the grid Table 3 2 Rating of grid OCPD 3 4 3 1 Connecting the inverter to the utility grid All electrical installations must be carried out in accordance with the local stan...

Page 13: ...n use a hydraulic crimp tool to crimp the terminal The crimped portion of the terminal must be insulated with heat shrinkable tube or insulating tape 1 Strip the end of AC cable insulating jacket abou...

Page 14: ...12 5 13 6 14 7 15 8 16 Meter RS485 B DRM 2 6 COM1 485 A DRM 3 7 COM1 485 B DRM 4 8 RefGen COM2 485 A Com DRM0 COM2 485 B V 12V V GND Figure 4 1 16pin COM Connector The following is the assembly diagra...

Page 15: ...box or any compatible 3rd party monitoring devices PPC or plant SCADA 4 Comm Monitoring 4 Comm Monitoring 29 28 4 1 Inverter monitoring connection Canadian Solar can provide optional accessories such...

Page 16: ...Comm Monitoring 4 Comm Monitoring 31 30 NOTE The PLC communication can not work with RS485 communication at the same time If already installed the PLC CCO for PLC communication on site then the RS485...

Page 17: ...n Connector 4 3 Meter Connection The inverter can work with a three phase smart meter to achieve Export Power Management function and or 24hour consumption monitoring function The Pin 1 and Pin 2 of t...

Page 18: ...service technicians only The inverter is customized according to the local grid standard before shipping There should be no requirement to set the standard NOTE The User Def function can only be used...

Page 19: ...the inverter see Specifications in section 10 may damage the inverter Although Canadian Solar inverters feature reverse polarity protection prolonged connection in reverse polarity may damage these p...

Page 20: ...ed DC POWER LED and LCD will be continuously lit 4 Canadian Solar inverters are powered from the DC side When the inverter detects DC power that is within start up and operating ranges the inverter wi...

Page 21: ...1 Information list Status Generating Power 0000W Grid Frequency F_Grid 00 00Hz Total Energy 0000000 kwh This Month 0000kwh Last Month 0000kwh Today 00 0kwh Yesterday 00 0kwh 10 sec 10 sec 10 sec 10 s...

Page 22: ...arm Message 2 Running message 3 Version 4 Daily Energy 5 Monthly Energy 6 Yearly Energy 7 Daily Records 8 Communication Data 9 Warning Message The following submenus are displayed when the Settings me...

Page 23: ...history of changing settings Only for maintance personel 7 Normal operation 7 Normal operation 7 4 3 Version The screen shows the model version of the inverter And the screen will show the software v...

Page 24: ...99 Figure 7 16 Selecting the User Def menu will access to the following submenu see Figure 7 17 Figure 7 17 OV G V1 400V OV G V1 T 1 0S Below is the setting range for User Def Using this function the...

Page 25: ...alue of total energy Use this function could allow user to revise the value of total energy to the same value as before If the monitoring website is used the data will be synchronous with this setting...

Page 26: ...not connected or logic interface relay is opened the inverter will display LimbyDRM and the inverter output power will be limited to zero 1 Select Initial Settings 2 Select DRM and set it to ON 7 5 10...

Page 27: ...ere are 4 settings in this menu as below 1 OFF 2 Meter in Load 3 Meter in Grid 4 Consumption Monitor OFF Functions are disabled Meter in Load Canadian Solar Smart Meter is connected in the load branch...

Page 28: ...als to one of three phase load power that is the lowest load power of a certain phase Figure 7 31 Inverter Meter 7 5 13 Restart HMI The function is used for restart the HMI This function is applicable...

Page 29: ...Test Figure 7 33 Selecting Fan Test displays the sub menu shown below Are you sure YES ENT NO ESC Fan Test is a factory test function Press the ENTER key to start the test Press the ESC key to return...

Page 30: ...t When operating the inverter LCD screen displays PID repairing information and the red light is on The Night Time PID Recovery function is always ON when AC is applied If maintenance is required and...

Page 31: ...xed 2 Check if the DSP connector to power board are fixed 1 Check inverter surrounding ventilation 2 Check if there s sunshine direct on inverter in hot weather 1 Use user define function to adjust th...

Page 32: ...ing current down below 0 5A Turn off the two DC switchs and fix the polarity issue Screen OFF with DC applied Inverter internally damaged 1 Do not turn off the DC switches as it will damage the invert...

Page 33: ...CSI 50K T400GL03 E Max output current Amps 83 6 3 N PE 220 380 230 400 Rated grid output current Amps 10 Specifications AC connection DC connection Display Communication connections MC4 connector OT...

Page 34: ...0 195 CSI 25K T220GL03 E Max output current Amps 72 2 3 N PE 220 Rated grid output current Amps AC connection DC connection Display Communication connections MC4 connector OT Terminal max 70 mm LCD Ca...

Page 35: ...ances and are properly ventilated Completed 5 Serial number Record the product serial numbers located on the side label Serial Numbers attached list 6 Solar modules Confirm PV module installation comp...

Page 36: ...0GL01 E CSI 8K T400GL01 E CSI 10K T400GL01 E 1 Switch the grid supply main Switch AC ON first 2 Switch the DC switch ON If the voltages of PV arrays are higher than start up voltage the inverter will...

Page 37: ...e front panel interface Completed Record current date time in Notes 6 Communication setting if avail Set communication with a unique address for each inverter Completed Record address in Notes 7 Machi...

Page 38: ...Output power Input DC voltage Insulation limit K PV start up voltage Grid V Max V Min Frequency Max Min Reactive compensation PF Configuration MPPT Individual MPPT Parallel Monitoring RS485 Ethernet...

Page 39: ...r to inverter site selection and installation 3 PHASE STRING INVERTERS CSIF ST 016 A 0 INSTALLER S NAME INSTALLER S SIGNATURE COMPANY DATE Inverter serial numbers 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 1...

Reviews: