background image

V I C T O R I A

V I C T O R I A

(20)

(21)

Show and Set Time-of-Day

Be sure to set the Time-of-Day

Setting the time-of-day can be important for determining filtration times and other background features.

When in the TIME menu, SET TIME will flash on the display if no time-of-day is set in the memory.

24-hour time display can be set under the PREF menu. 

Note:

This note refers to systems that do not keep track of Time-of-Day when powered down.

If power is interrupted to such a system, Time-of-Day is not stored. The system will still operate and all other user settings

will be stored. If filter cycles are required to run at a particular time of day, resetting the clock will return the filter times

to the actual programmed periods.

When such a system starts up, it defaults to 12:00 Noon, so another way to get filter times back to normal is to start up

the spa at noon on any given day. SET TIME will still flash in the TIME Menu until the time is actually set, but since the spa

started at noon, the filter cycles will run as programmed.

Flip (Invert Display)

04-11-09

Restricting Operation

The control can be restricted to prevent unwanted use or temperature adjustments. Locking the panel prevents the controller 

from being used, but all automatic functions are still active.

Locking the Temperature allows Jets and other features to be used, but the Set Temperature and other programmed settings

cannot be adjusted.

Temperature Lock allows access to a reduced selection of menu items. These include Set Temperature, FLIP, LOCK, UTIL, INFO 

and FALT LOG.

08-06-09

Light Timer 

Programming

Light Timer Option

If LITE TIMR does not appear 

in the Main Menu, the Light 

Timer feature is not enabled 

by the manufacturer. 

When available, the Light 

Timer is OFF by default.

Sub-Menu Detail – Set Light Timer

Unlocking

This Unlock sequence may be used from any screen that may be displayed on a restricted panel. If the panel has both an UP and 

a Down button, the ONLY button that will work in the Unlock Sequence is the UP button.  The temperature will not Unlock if the 

Unlock sequence is done while the panel is displaying “LOCK”.

Sub-Menu Detail – Unlocking the Set Temperature or All Buttons

04-21-09

Summary of Contents for Victoria UV Spa

Page 1: ...V I C T O R I A Victoria UV Spa Owners Manual 218 x 218 x 82cm 86 x 86 x 33 KH 10025 For Service Support please contact us anytime support canadianspacompany com canadianspacompany com...

Page 2: ...l result in voiding the manufacturer s warranty 16 Do not bring any object into the spa that could damage the spa shell 17 Never insert any object into any opening 18 WARNING Do not sit on the spa cov...

Page 3: ...AIN VALVE Valve located on the outside of spa cabinet used to drain water from the spa A garden hose can be attached to the drain valve EQUIPMENT BAY Located under the spa shell covered by access pane...

Page 4: ...a Status LED provides convenience right at your finger tips Check the status of your spa by looking at the colour of the LED light from afar NORMAL OPERATION REMINDER NOTIFICATIONS NEEDS ASSISTANCE IM...

Page 5: ...position Draining your Spa Using drain valve IMPORTANT Before draining your spa shut off the electrical breaker connected to the spa Accessing your spa controls To access the Control Pack undo the 3 s...

Page 6: ...DIP switches A2 and A3 on ON and DIP switch A5 on OFF B 2 x Single Phase live 1 neutral 1 live 2 neutral 2 ground 230VAC 50 60Hz 2 16A Circuit Breaker rating 20A max each phase line In 2x16A Service...

Page 7: ...pa Flush Annually flush the spa to remove bio film that has attached to the interior of the spa pipes KA 10164 Spa Functions Pumps Press the Jets 1 button once to turn pump 1 on or off and to shift be...

Page 8: ...Spa Company channel pH LOW pH HIGH pH NORMAL 7 2 7 6 Reduced ef cacy of disinfection Corrosion of metals Skin eye irritation Unpleasant odour Reduced ef cacy of disinfection Skin eye irritation Forms...

Page 9: ...ycle duration Based on usage adjust filtration cycle duration High solids content See common water problem section Settings 2 x Pumps standard Simple Options Press Menu button until you reach the mode...

Page 10: ...ump off and on will help it to prime Do not do this more than 5 times If the pump will not prime shut off the power to the spa and call for service Important A pump should not be allowed to run withou...

Page 11: ...tarted at noon the filter cycles will run as programmed Flip Invert Display Restricting Operation The control can be restricted to prevent unwanted use or temperature adjustments Locking the panel pre...

Page 12: ...will last for 1 hour unless the mode is exited manually Drain Mode Some spas have a special feature that allows a pump to be employed when draining the water When available this feature is a component...

Page 13: ...ing This typically requires observing the output of each pump separately and is generally not possible in normal operation Priming Mode lasts 4 minutes but you can exit it earlier by pressing any Temp...

Page 14: ...7 days can be specified by the Manufacturer Press a Temperature button to reset a displayed reminder message Alternates with temperature or normal display Appears on a regular schedule e g every 7 day...

Page 15: ...nce or protection is essential Canadian Spa Co warrants the cover for the period of two 2 years Defects caused by misuse or insufficient care are not covered by the warranty TERMS CONDITIONS AND LIMIT...

Reviews: