background image

9

DRAIN

ELECTRICAL*

GLACIER AO

3

(purchase separately)

Twist and pull out the drain valve to access the 
built drain and attach your garden hose for better 
convenience. We recommend that you change your 
water seasonally.

Free of pollution, glaciers contain

 the world’s most 

pristine water.

 Our Glacier AO

3

P system sterilizes up 

to 99.9% of bacteria in your hot tub, reducing chemical 
usage by up to 80% and leaving your water crystal 
clear!

Plug and play models have designated electrical panels 

so please keep this in mind when placing your tub in its 

location. All 240V hot tubs allow you to choose which 

panel you would like to drill a hole into for your wiring to 
pass through.

PUMPS

With up to 

400% more hydro massage configurations, 

Canadian Spa Company’s multi-speed pumps give you 
endless combinations of jet speeds and power. From 

relaxation to aquatic exercise to marathon training, our 
pumps can really do it all. 

9

CONTROL PACK & HEATER

Our control pack software design incorporates patented 
technology using a microprocessor to intelligently 
monitor the hot tub water temperature and detect a 
runaway pump or stuck relays.

FOR MORE HELP GUIDES VISIT US AT:

support.canadianspacompany.com

1-877-909-7727

Summary of Contents for HURON GL SPA

Page 1: ...l 60Hz Electrical 240V 50A Weight 850 lbs Dry 3500 lbs Filled Water Capacity 1200 L Jet Count 46 Seat Count 6 Size 84 x 84 x 35 Pump s 2 x 2 Speed 5 HP Heater s 1 x 5 5 kW Filter s 1 x 50sq ft Glacier Antimicrobial Filter KA 10082 ...

Page 2: ...components for example cable additional speakers headphones additional audio video components etc to system 11 CAUTION Risk of Electrical Shock Do not service this product yourself as opening or removing audio covers may expose you to dangerous voltage or other risk of injury Refer all servicing to qualified service personnel 12 CAUTION Risk of Electrical Shock When the power supply connections or...

Page 3: ...new spa Add Chemicals Wait for Water to Heat Enjoy Power On CA 1 877 909 7727 US 1 844 879 7727 CANADIAN SPA CO Insert Filters Fill Hot Tub Register Warranty Electrical SPA CHEMICAL S TA R T U P G U I D E canadianspacompany com Once your hot tub is filled install your new Glacier Antimicrobial Filters Remove the lid and fill the hot tub with water through the filter housing Temp up Temp Down Left Rig...

Page 4: ...lling your hot tub in freezing temperatures In colder temperatures please make sure to place a space heater inside the cabinet immediately after delivery for 24 to 48 hours before installation to prevent startup issues A licensed electrician can install the wiring by drilling a hole into any panel and terminating the connection at the control pack All hot tubs must be placed on a proper base that ...

Page 5: ...240V GFCI Electrical Installation Neutral Terminal Hot Terminal Hot Terminal Ground Terminal 1 2 3 4 Please refer to wiring diagram inside of spa pack cover for correct terminal installation Control Pack ...

Page 6: ...rol Valve 1 Air Control Valve Speaker 2 3 4 FEATURE FUNCTIONS 5 6 Suction Intake Aromatherapy LED Cup Holder 6 Temp up Temp Down Left Right JETS 1 JETS 2 Control Centre www canadianspacompany com 2 3 6 4 2 1 1 5 1 6 1 ...

Page 7: ...nd turn them off on to customize your spa to your satisfaction Directional Massage AIR CONTROL VALVE SUCTION INTAKE AROMATHERAPY Open and close this valve to inject air bubbles into the jet stream The warm air from inside the cabinet is mixed with the water to help maximize the hydrotherapy experience Place the aromatherapy beads inside the canister to mix in with the air valves to release scented...

Page 8: ...er AO3 P Purchase separately Electrical 1 2 3 4 5 Control Pack Heater Drain EQUIPMENT LOCATIONS 8 1 TEMP UP TEMP DOWN LIGHT JETS 1 INVERT JETS 2 BLOWER JETS 1 JETS 2 LIGHT HEAT www canadianspacompany com 1 2 3 4 5 1 ...

Page 9: ...keep this in mind when placing your tub in its location All 240V hot tubs allow you to choose which panel you would like to drill a hole into for your wiring to pass through PUMPS With up to 400 more hydro massage configurations Canadian Spa Company s multi speed pumps give you endless combinations of jet speeds and power From relaxation to aquatic exercise to marathon training our pumps can reall...

Page 10: ...ended for Summer months D Light Multiple colour choices for your custom experience E Cleanup Cycle Pump will run 30 min after spa use to filter and clean spa for 30 min F Jets 1 Pump 1 is on Note longer lines for high speed G Jets 2 Pump 2 is on Note short lines for low speed H Temperature Range Temperature can be set between 80 F and 104 F I SET Appears when changing settings J Filter Cycle Indic...

Page 11: ...P UP or TEMP DOWN button to set the number of hours you would like your filtration cycle to run every 12 hours Press MENU again to complete action PRESS TEMP UP PRESS Press MENU button until your screen flashes FLIP Press TEMP UP or TEMP DOWN button to set which orientation you would like for the screen to display Press MENU again to complete action PRESS PRESS TEMP UP OR OR TEMP DOWN TEMP DOWN PR...

Page 12: ...lkalinity pH Chlorine Alkalinity Booster Adjust alkalinity level to 80 150 ppm use pH Down to reduce see bottle for directions Wait 30 mins after adding pH Up pH Down Adjust pH level to 7 2 7 6 see bottle for directions Wait 30 mins after adding Chlorine Granules Add 15g per 1000L Wait 30 mins after adding YOUR STARTER KIT USING YOUR CHEMICALS ENJOY ...

Page 13: ...TER According to replacement schedule CHANGE WATER Drain and refill your water CHECK UV C BULB purchased separately Ensure LED is on during filter cycle BALANCE Balance you water according to Test Strip readings SPA BALL Replace your Spa Ball once it begins to sink below the surface of your water FILTER FREE Soak filter overnight and rinse to clean you filters YEARLY FOR MORE HELP GUIDES VISIT US ...

Page 14: ...ilm of any kind Damage to the spa surface caused by contact with unapproved cleaners or solvents Damage caused by the operation of the spas at water temperatures outside of the range of 2 40 degrees Celsius Damage caused by unapproved sanitizer such as calcium hypochlorite tri chlor type chlorine or any sanitizing chemical that may remain undissolved on the spa surface Damage caused by failure to ...

Reviews: