Canadian Solar Dymond CS6K-245P-FG Installation Manual Download Page 6

EN-Rev IM-FDM-EN/1.6 Copyright © March 2017. Canadian Solar Inc.

6 | 

· 

Do not 

drop or place objects (such as tools) on  

the modules. 

· 

Do not 

carry modules on your head.

· 

Do not

 use sharp instruments on the modules. 

· 

Do not

 place modules on top of each other

· 

Do not

 leave modules unsupported or unsecured. 

· 

Do not

 change the wiring of bypass diodes.

·  Keep all electrical contacts clean and dry.  

PRODUCT IDENTIFICATION

·  Each module is equipped with two identical bar-

codes (one inside the laminate under the front 
glass, the second on the rear side of the module) 

that act as a unique identifier. Each module has a 

unique serial number containing 14 digits.

·  A nameplate is also affixed to the rear glass of 

each module. This nameplate specifies the model 

type, as well as the main electrical and safety cha-
racteristics of the module.

5.0  

MODULE INSTALLATION

PRECAUTIONARY MEASURES  
AND GENERAL SAFETY

·  Prior to installing modules please obtain infor-

mation about any requirements and necessary 
approvals for the site, installation and inspection 
from the relevant authorities.  

·  Check applicable building codes to ensure that  

the construction or structure (roof, facade,  
support, etc.) can bear the module system load. 

·  Canadian Solar Inc. double glass solar modules 

have been qualified for Application Class A 

(equivalent to Safety Class II requirements). 
Modules rated under this class should be used in 
systems operating at voltage above 50 V or power 
above 240 W, where general contact access is 
anticipated.

DO NOT STAND OR STEP 

on the  

modules under any circumstances.

Localized heavy loads may cause severe micro-
cracks at cell level, which in turn may compromise 
module reliability. Failure to comply with the above 
caution will void Canadian Solar Inc.’s warranty.

SYSTEM FIRE RATING

·  The fire rating for this module is only valid when 

the product is installed as specified in the mechani

-

cal mounting instructions.

·  Canadian Solar Inc. double glass modules 

have been certified by CSA as Type 3 for fire 

performance.

·  When installing the modules on rooftop, please  

ensure the assembly is mounted over a fire resistant

 

roof covering rated for the application. 

·  A photovoltaic system composed of UL1703 

certified modules mounted on a UL2703 certified 

mounting system should be evaluated in combina-
tion with roof coverings in accordance with UL1703 

standard, with respect to meeting the same fire 
classification as the roof assembly. 

·  Mounting systems with a System Fire Class Rating 

(Class A, B or C), tested in conjunction with fire 

rated “Type 3” rated modules, are considered ac-
ceptable for use with Canadian Solar Inc. modules, 
provides the mounting system does not violate any 
other requirements of this manual. 

·  Any mounting system limitations on inclination or 

accessories required to maintain a specific System 
Fire Class Rating should be clearly specified in the 
installation instructions and UL2703 certification of 

the mounting system supplier. 

   

ENVIRONMENTAL CONDITIONS

·  The module is intended for use in general open-air 

climates, as defined in IEC 60721-2-1: Classification 
of environmental conditions Part 2-1: Environmental 

conditions appearing in nature - temperature and 
humidity.   

·  Please consult the Canadian Solar Inc. technical 

support department for more information on the 
use of modules in special climates.

Please note

Summary of Contents for Dymond CS6K-245P-FG

Page 1: ...INSTALLATION MANUAL OF DYMOND MODULE For professional use only...

Page 2: ...EN Rev IM FDM EN 1 6 Copyright March 2017 Canadian Solar Inc...

Page 3: ...3 0 MECHANICAL ELECTRICAL SPECIFICATIONS 4 0 UNPACKING AND STORAGE 5 0 MODULE INSTALLATION 5 1 MODULE WIRING 5 2 MODULE GROUNDING 6 0 MOUNTING INSTRUCTIONS 7 0 MAINTENANCE AMENDED EDITIONS AND DATES...

Page 4: ...cluding without limitation bodily harm injury or damage to property in connection with handling PV modules system installation or compliance or non compliance with the instructions set forth in this m...

Page 5: ...rical Ratings Main electrical charac teristics under STC are also stated on each module label The maximum system voltage for double glass module type is 1000V UL and 1500V IEC Under certain conditions...

Page 6: ...heavy loads may cause severe micro cracks at cell level which in turn may compromise module reliability Failure to comply with the above caution will void Canadian Solar Inc s warranty SYSTEM FIRE RA...

Page 7: ...ing Only modules with similar electrical outputs should be connected in the same series to avoid or minimize mismatch effects in arrays To minimize risk in the event of an indirect light ning strike a...

Page 8: ...ting system using UV resistant cable ties Protect exposed cables from damage by taking appropriate precautions e g placing them inside a plastic conduit Avoid exposure to direct sunlight A minimum ben...

Page 9: ...overlap the module by 13 mm to 15 mm 5 To ensure the thickness of the clamps is at least 3 mm Clamp positions are of crucial importance for the reliability of the installation the clamp centerline mu...

Page 10: ...8 8 9 92 CS6K 245M FG 245 30 3 8 09 37 4 8 61 15 1658 992 5 8 65 3 39 1 0 23 in without junction box and corner protector 23 CS6K 250M FG 250 30 4 8 22 37 5 8 74 CS6K 255M FG 255 30 5 8 35 37 7 8 87 C...

Page 11: ...305 32 7 9 33 39 9 9 91 CS6K 310MS FG 310 32 9 9 43 40 1 9 99 CS6X 290P FG 290 35 9 8 08 44 4 8 64 15 1968 992 5 8mm 77 5 39 1 0 23 in without junction box and corner protector 27 5 CS6X 295P FG 295 3...

Page 12: ...A Clamping on module long side four clamp points Mounting rails must run perpendicularly to the module long side Clamping Location Illustration Illustration A Clamping on module long side six clamp p...

Page 13: ...mp length 100 mm four clamps A 380 20 mm see illustration A Downforce load 2400 Pa Uplift load 2400 Pa VDE CSA 2 C 2 Profi clamp wide 3 8 mm clamp length 200 mm four clamps A 380 20 mm see illustratio...

Page 14: ...ngth 100 mm six clamps A 250 20 mm B 579 20 smm see illustration B Downforce load 5400 Pa Uplift load 2400 Pa VDE CSA 2 F 1 Akcome Metals Technology Suzhou Co Ltd AK EC DG End clamp AK MC DG Middle cl...

Page 15: ...i clamp wide 3 8 mm clamp length 130 mm four clamps A 440 20 mm see illustration A Downforce load 2400 Pa Uplift load 2400 Pa VDE CSA 3 C 2 Profi clamp wide 3 8 mm clamp length 250 mm four clamps A 44...

Page 16: ...1 End clamp PW CS 02 Middle clamp clamp length 100 mm six clamps A 300 20 mm B 684 20 mm see illustration B Downforce load 2400 Pa Uplift load 2400 Pa VDE CSA 3 E 4 PW CS 01 End clamp PW CS 02 Middle...

Reviews: