Camtec Joerns CareChair RCCC550B User & Service Manual Download Page 2

2

Joerns® Transport Chairs
CareChair

© 2016 Joerns Healthcare • 6110303 RevA • 16-2391

Important Precautions 

Caution: 

Rotating Parts. Keep fingers and arms clear 

of chair’s moving parts when mechanism is operating.

Caution: 

Pinch Points. While adjusting back or arm 

rests, patient’s arms must be inside arm rests.

Caution: 

Pinch Points. Keep objects away from these 

areas while chair is in motion.

Caution: 

Pinch Points. Keep objects away from arm 

rest while lowering.

Warning: Possible Injury Or Death. 

Do not leave 

unattended when on a sloped surface. Lock casters 

when not in use or unattended. Failure to do so could 

result in injury or death.

Caution: 

Keep feet clear of casters. Make sure 

casters are locked before transferring patient.

Warning: Possible Injury Or Death. 

Lock casters 

when not in use or unattended. Failure to do so could 

result in injury or death.

Caution: 

Use tilt function to level the arm rest before 

going into the transfer (stretcher) position. Raise arm 

rest when patient is in stretcher position.

Caution: 

Make sure that the pendant cord is properly 

positioned before operating the chair. Do not allow 

cord to get caught in the moving parts of the chair.

Warning:

 Possible Injury Or Death. Resident/patients 

may become entangled in pendant cord. Resident/

patients with reduced mental acuity should not be 

allowed access to pendant. Unsupervised use of 

pendant could result in injury or death.

Warning: Possible Injury. 

Keep all objects from 

under chair. Certain parts under the chair raise and 

lower when the chair is in motion.

Caution: 

Make sure I.V. rod and oxygen tank are fully 

inserted into their holders.

Caution: 

Make sure the power cord is unplugged and 

stored before moving chair.

Warning: Possible Shock Hazard. 

Do not operate 

this device if the power cord or any of the cords 

coming from the control module are cut, frayed, 

damaged or loosely connected.

Warning: Possible Injury. 

Do not place any body 

parts into frame while operating. Stand Clear of the 

chair’s frame before operating.

Warning: Possible Shock Hazard. 

Do not service the 

chair without first disconnecting the power cord.

Caution: 

Caster lock is not designed to slow motion 

of the CareChair while in motion. Do not engage lock 

pedal while moving the chair.

Caution: 

Pinch points possible during manual 

adjustment of foot rest. Always use both hands when 

raising or lowering the leg rest

Warning: Possible Injury Or Death.

 CareChair safe 

working load is based per model. This is total weight 

counting resident/patient, accessories, linens and any 

other equipment or persons likely to be on chair. Do 

not exceed safe working load. Exceeding the safe 

working load could result in property damage, injury 

 

or death.

Caution: 

Risk of Personal Injury. In the event worn or 

broken part(s) are identified, remove the device from 

service until repairs are made.

Caution: 

Risk of Personal Injury. Do not sit on 

 

head or foot end when unit is in the horizontal 

(stretcher) position.

Warning:

 

Possible Injury. 

Adjust arm rests only after 

the resident/patient is safely positioned in the chair. 

Failure to do so could result in injury.

Warning:

 

Possible Injury. 

Prior to operation,  

ensure chair has space in the room to tilt and 

 

recline as needed.

Caution: 

Risk of Personal Injury. Use the push/pull 

handles integrated to the back section to move the 

chair. Recommend 2 attendants to push occupied 

 

850 lb. chair.

Warning:

 

Possible Injury. 

Restraining belt is available 

for safe operation. Caregiver is obligated to assess if 

the restraining belt is required to ensure safety of the 

patient. Serious injury can occur in the event of a fall 

from the chair.

Caution:

 Seat belt adjustment may be required for 

patient comfort when articulating the chair.

Caution: 

Do not use the footrest as a step when 

patient sits or stands from the chair.

Warning: Possible Injury Or Death.

 If using 

accessories not manufactured, marketed, or provided 

by Joerns Healthcare for CareChairs, consult with the 

manufacturer for compatibility and limitations prior to 

use. Failure to do so may result in injury or death.

Summary of Contents for Joerns CareChair RCCC550B

Page 1: ...User Service Manual Joerns Transport Chairs CareChair Tilt in Space Chair with Stretcher Model RCCC550B RCCC650B RCCC850B To avoid injury read user s manual before using The Caregiver s Choice TM ...

Page 2: ...parts into frame while operating Stand Clear of the chair s frame before operating Warning Possible Shock Hazard Do not service the chair without first disconnecting the power cord Caution Caster lock is not designed to slow motion of the CareChair while in motion Do not engage lock pedal while moving the chair Caution Pinch points possible during manual adjustment of foot rest Always use both han...

Page 3: ...pright sitting position to a full stretcher position They tilt back to redistribute the patient s weight aiding in comfort and pressure relief The chairs also tilt forward to assist in patient s egress When in the supine position the patient can receive treatment emergency care or be more easily transferred from the chair to a bed While in the stretcher mode the chair has the ability to go into th...

Page 4: ...each 80 of the battery capacity level We recommend a charging time up to 10 hours which gives 100 capacity To achieve optimum battery life keep the chair plugged in at all times when chair is stationary Environmental Conditions Operating Conditions Ambient Temperature 10 C to 40 C Relative Humidity 30 to 75 Non Condensing Atmospheric Pressure 700 hPa to 1060 hPa Protected Against Splashing Water I...

Page 5: ...eeping it plugged in when not in use You cannot overcharge the system by leaving the unit plugged in The control box duty cycle max 10 or 2 minutes continuous use followed by 18 minutes not in use The control box has electronic overload protection The current will be cut off when the control box is not in use Pendant Functions Figure 1 1 Button converts chair to horizontal position 2 Button conver...

Page 6: ...p to desired height Leg rest will automatically lock into desired position To Lower 1 Raise leg rest slightly and hold 2 Move lever to unlock position 3 Lower leg rest Leg Rest Length Adjustment Figure 5 1 Hold foot rest 2 Swing and hold locking bar 3 Move foot rest to desired length 4 Release locking bar and move foot rest slightly until pin snaps into locking hole Arm Rest Adjustment Figure 6 1 ...

Page 7: ... the locking knob and extend the rod to the desired height then tighten the locking knob 4 When not in use collapse the rod and store in the storage tube under the chair Patient Tray 1 Insert tube on tray into tube on the left hand arm rest 2 When tray is in place tighten tray locking knob Note The tray cannot be used as a restraint Note Tray is not available on the 850 model at this time Commode ...

Page 8: ...otentially hazardous to the environment if they are not disposed of properly Heavy metals corrosive acids and lead may seep out from batteries that are carelessly disposed potentially contaminating bodies of water and harming wildlife and or humans Dispose of worn out batteries at your local recycling center in the same manner as a lead acid automotive battery Joerns Healthcare Technical Support c...

Page 9: ...er socket If actuator still does not operate replace actuator Pendant No functions work Check that pendant is properly plugged in Some functions work and some do not Replace pendant Functions working opposite of how they are supposed to operate Reverse actuator plugs in controller Chair does not roll straight Position of caster pedal Adjust pedal to steer position Leg rest is too high Leg rest pos...

Page 10: ...10 Joerns Transport Chairs CareChair 2016 Joerns Healthcare 6110303 RevA 16 2391 Appendix A Wiring Diagram ...

Page 11: ...11 Joerns Transport Chairs CareChair 2016 Joerns Healthcare 6110303 RevA 16 2391 Appendix A Frame Assembly ...

Page 12: ...12 Joerns Transport Chairs CareChair 2016 Joerns Healthcare 6110303 RevA 16 2391 Appendix A Chassis Assembly ...

Page 13: ...13 Joerns Transport Chairs CareChair 2016 Joerns Healthcare 6110303 RevA 16 2391 Appendix A Back and Arm Assembly ...

Page 14: ...14 Joerns Transport Chairs CareChair 2016 Joerns Healthcare 6110303 RevA 16 2391 Appendix A Seat and Leg Assembly ...

Page 15: ...15 Joerns Transport Chairs CareChair 2016 Joerns Healthcare 6110303 RevA 16 2391 Appendix A Upholstery Assembly ...

Page 16: ...16 Joerns Transport Chairs CareChair 2016 Joerns Healthcare 6110303 RevA 16 2391 Appendix A Back Frame Assembly ...

Page 17: ...17 Joerns Transport Chairs CareChair 2016 Joerns Healthcare 6110303 RevA 16 2391 Appendix A Label Locations ...

Page 18: ...12 102702 0 Shaft Front Frame Pivot 13 102703 0 Shaft Seat Back Pivot 14 39001552 Pinch Shield Outer LH 15 39001553 Pinch Shield Outer RH 16 39001554 Pinch Shield Inner LH 17 39001555 Pinch Shield Inner RH 18 102749 0 Shaft Pinch Shield 2 062 LG 19 102782 0 Wear Strip Tilt Chair Side Panel 20 103311 0GY 103311 0SL Rod Connecting Wheels 21 105122 0 Spacer Pinch Shield 22 23 24 25 26 27 28 29 390015...

Page 19: ...0016 0 Nut 20 Hex ESNA 48 900045 0 Nut 5 16 18 Hex ESNA 49 900049 0 Detent Valcro 8 141 50 900050 0 Buckle 2 Black 51 900051 0 Plunger Southco 52 900053 0 Screw 10 x LG Flat Head Phillips 53 900059 0 Screw 20 x LG Socket Set Dog Point 54 900063 0 Bolt Hex 5 16 18 x 2 LG 55 900070 0 Dowel Pin 3 32 DIA x LG 56 900073 0 Spring Compression 57 208 0510 Washer Flat 10 Old Part Number 900075 0 58 900076 ...

Page 20: ... 91 208 0509 Washer Flat 8 Old Part Number 903205 0 92 903212 0 Shoulder Bolt DIA x LG 93 903502 0 Label Warning Keep Feet Clear 94 903526 0 Label Leg Length Release Pin RH 95 903527 0 Label Leg Length Release Pin LH 96 903528 0 Label Leg Elevation On Off RH 97 903529 0 Label Leg Elevation On Off LH 98 903530 0 Label Caution Pinch Area 99 903531 0 Label Arm Adjust Pin RH 100 903532 0 Label Arm Adj...

Page 21: ...g Cater Lever Green 128 904071 0 Cable Clamp 3 16 Nylon 129 904098 0 Terminal Ring 16 14 AWG 130 904120 0 Cable Clamp Steel Vinyl Coated 131 39001563 Actuator Linak 374mm Install 192mm Stroke 132 39001564 Actuator Linak 300mm Install 92mm Stroke 133 904182 0 Pendant CareChair Linak 134 39001565 Controller CareChair Linak 135 39001566 Battery CareChair Linak 136 904190 0 Pin Clevis 10mm x 60mm LG 1...

Page 22: ... Tie Tube Adj Lever 39001551GY 39001551SL 39001541GY 39001541SL 39001542GY 39001542SL 207 Weldment Leg Support LH 39001548GY 39001548SL 39001544GY 39001544SL 39001546GY 39001546SL 208 Weldment Leg Support RH 39001547GY 39001547SL 39001543GY 39001543SL 39001545GY 39001545SL 209 210 211 212 213 Weldment Foot Plate 39001549GY 39001549SL 39001533GY 39001533SL 39001540GY 39001540SL 214 215 Assembly Cus...

Page 23: ...23 Joerns Transport Chairs CareChair 2016 Joerns Healthcare 6110303 RevA 16 2391 Notes ...

Page 24: ...air unless performed by or authorized in writing by Joerns Healthcare will void this warranty Parts Joerns CareChairs contain various parts that wear from normal use such as batteries These parts are not covered under the stated warranty but are covered for 90 days after date of delivery Joerns Healthcare s obligation under this warranty is limited to supplying replacement parts servicing or repla...

Reviews: