Camsat CAM8h-Multi2/AHD User Manual Download Page 8

EU

EU

MADE IN

POLAND

MADE IN

POLAND

CAM8h-Multi2/AHD

Note: CAM8h-Multi2/AHD  enables using special channels and frequency ranges depen-

ding on the country or region! Please follow the standards used in your country. Do not 
use these settings if you are not sure what standards are used in your region.

2. Setting of operating channels

FREQUENCY SELECTION

CAUTION

In order to ensure a stable radio connection, the antennas must be in a line of sight. A 
100% line of sight must also be provided in the  rst Fresnel zone. This means that for the 
frequency of 5.8 GHz and the distance of 600 m, an unobstructed space for a radio beam 
in the radius of at least 3.9 m (r in the dr point) must be provided.

3. Terminals description / controls :

1 2 3 4

1

EU

5855 MHz

Channel

1 2 3 4

2

EU

5820 MHz

Channel

1 2 3 4

3

EU

5780 MHz

Channel

1 2 3 4

4

EU

5745 MHz

Channel

1 2 3 4

5

nonEU

5715 MHz

Channel

1 2 3 4

6

nonEU

5680 MHz

Channel

1 2 3 4

7

nonEU

5645 MHz

Channel

1 2 3 4

8

nonEU

5610 MHz

Channel

1 2 3 4

9

nonEU

5575 MHz

Channel

1 2 3 4

10

nonEU

5540 MHz

Channel

1 2 3 4

11

nonEU

5505 MHz

Channel

1 2 3 4

12

nonEU

5470 MHz

Channel

1 2 3 4

13

nonEU

5435 MHz

Channel

1 2 3 4

14

nonEU

5400 MHz

Channel

1 2 3 4

15

nonEU

5365 MHz

Channel

1 2 3 4

16

nonEU

5330 MHz

Channel

FREQUENCY SELECTION

    

 

  !"#$%#

&'#(#)*(

$ +  ,-. /0 1
+ + 

  

$ +  2*034454.6 
1

7 + %8 1

7+ 5

(9*#8(

 $ 1  1
3 6

7+ 0 +  1

3 6

 

  

+ 3 6

!+ &'#:2*

 

!2*+ :&'#  

 1+   + 2*3($
; 6

7

Summary of Contents for CAM8h-Multi2/AHD

Page 1: ...www camsat com www camsat com Multi set for wireless transmission two images from the AHD and PAL cameras in the ISM 5 8 GHz User s Manual CAM8h multi2 AHD ...

Page 2: ...ystems wherever the need is of high quality stable video connection high resolution AHD technology The contents of this manual comprise proprietary information of CAMSAT and are intended only for use by purchasers of the equipment described herein In order to copy or use any part of this manual for purposes other than the application or maintenance of the described equipment it is required that th...

Page 3: ...s 3 Before you begin Quick start 1 Installation 2 Setting of operating channels 3 Terminals description controls 8 4 Technical data 9 5 Recommendations 10 Warranty general conditions 11 Used equipment storage 12 Declaration of conformity 13 3 4 5 5 5 6 6 7 I II III V VI VII EU EU MADE IN POLAND MADE IN POLAND CAM8h Multi2 AHD I IV ...

Page 4: ...ght be contradictory to laws applicable in selected countries The device is suitable for use in the European Union This devices have been designed and manufactured with the utmost care for the safety of its installers and users For safety reasons observe all the guidelines in this manual and peripheral devices manuals such as the PC or IP camera Before installing the devices carefully read the ent...

Page 5: ...sferred to a room where the temperature is higher than where it has previously been kept water vapour may condensate inside its casing which will prevent its proper use Wait until the condensed water evaporates R TTE declaration of conformity Distances and interferences The transmission distance may vary depending on the frequency environment radio waves buildings weather conditions etc 1 When the...

Page 6: ...AHD Rx Zip ties User Manual Declaration of Conformity Guarantee Certi cate High quality stable video transmission in the AHD M AHD L CVBS and PAL standards Supported resolution 720p 960p 960h and PAL NTSC Total of 16 channels including 4 channels intended for operation in the EU European Union EU operating band from 5725 MHz to 5875 MHz and an additional band from 5350 MHz to 5875 MHz for some oth...

Page 7: ...Begin by activating the rst transmission link and only once it is fully operational proce ed to activate another link in the same way This will facilitate activating and selecting spur operating channels Connect the video cables to the BNC or UTP port and the audio cables only for PAL NTSC as speci ed in the description Set the required channel as per the table Antenna polarisation vertical instal...

Page 8: ...tance of 600 m an unobstructed space for a radio beam in the radius of at least 3 9 m r in the dr point must be provided 3 Terminals description controls 1 2 3 4 1 EU 5855 MHz Channel 1 2 3 4 2 EU 5820 MHz Channel 1 2 3 4 3 EU 5780 MHz Channel 1 2 3 4 4 EU 5745 MHz Channel 1 2 3 4 5 nonEU 5715 MHz Channel 1 2 3 4 6 nonEU 5680 MHz Channel 1 2 3 4 7 nonEU 5645 MHz Channel 1 2 3 4 8 nonEU 5610 MHz Ch...

Page 9: ...uality switching power supply other than the one dedicated by manufacturer for example CAMSAT ZS12 1A 3 It is not recommended to connect the transmitter and receiver to a common power supply It is allowed to connect several transmitters to one power supply and use a separate power supply for multiple receivers 4 It is recommended to mount the receivers at least 6 7 m away from other wireless digit...

Page 10: ...o reasons inherent to the sold device 5 Warranty repairs will be carried out in the shortest possible amount of time not exceeding 14 days counting from the moment of accepting the device for servicing If parts need to be imported the repair deadline may be extended After the repairs have been car ried out the warranty period will be extended by the repair time resulting from device repair or malf...

Page 11: ...dled improperly Improper waste disposal is subject to penalties provided for in the appropriate regulations The mark presented to the left informs that this electrical or electronic device after its use has ended cannot be thrown together with household refuse The device should be delivered to a specialised collection point Detailed information about the closest collection point is available from ...

Page 12: ...11 EU EU MADE IN POLAND MADE IN POLAND CAM8h Multi2 AHD VIII Declaration of conformity ...

Page 13: ...every country It is your responsibility to be adequate settings of the complying with the applicable laws in the country or region Producer CAMSAT Gralak Przemysław Ogrodowa 2a 86 050 Solec Kujawski Poland Offer and information www camsat com Service serwis camsat com pl Technical support Mon Fr 8 00 AM 4 00 PM tel 48 52 387 10 97 Warning about the possible risk of high voltage exposure caused by ...

Page 14: ......