EN
26
Condition 1: Zero functions
When total sum of all loads on scale ≤4 % of scale’s max weight
capacity (4% = 80 g when weight capacity is 2000 g or 200 g
when the weight capacity is 5000 g)
The LCD will show ”-----” or ”0 g” each time the ZERO button is
pressed Wait a moment if ”-----” appears on the display ”0 g”
and an ”o” icon at the same time in the corner of the LCD mean
the ”Zero” function is activated max weight capacity remains
unchanged
Condition 2: Tare function
When the total sum of all loads on the scale > 4 % of the scale’s
max weight capacity (4 % = 80 g when the weight capacity is
2000 g or 200 g when the weight capacity is 5000 g)
The LCD will show ”-----” or ”0 g” each time the ZERO button is
pressed Wait a moment if ”-----” appears on the display ”0 g” and
a (T) icon (tare) at the same time on the upper left corner of the
LCD mean the ”Tare” function is activated max weight capacity is
reduced by the total weight of all loads
Under this condition:
By pressing ZERO, you can see the total weight of all loads on the
scale If you want to weigh more loads, just press ZERO to reset the
LCD reading to ’0’ again
AUTO SHUT OFF
Auto shut-off occurs if display shows ’0’ or shows the same weight
reading for one minute
g
ZE
RO
g
ZE
RO
g
g
g
g
g
g
1 min